Honeywell GLD Series Rod Limit Switch, 1 NC/1 NO, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 6A
- N° de stock RS:
- 308-1901
- Référence fabricant:
- GLDB01A4J
- Fabricant:
- Honeywell
Sous-total (1 unité)*
115,30 €
(TVA exclue)
139,51 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 34 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
- Plus 60 unité(s) expédiée(s) à partir du 31 août 2026
- Plus 60 unité(s) expédiée(s) à partir du 28 décembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 115,30 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 308-1901
- Référence fabricant:
- GLDB01A4J
- Fabricant:
- Honeywell
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Rod | |
| IP Rating | IP66 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | Screw | |
| Series | GLD | |
| Minimum Operating Temperature | -40°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 85°C | |
| Width | 30.5mm | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Length | 68.5mm | |
| Depth | 26.35mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.12N | |
| Mechanical Life | 10000000Cycles | |
| Conduit Entry | PG13.5 | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Rod | ||
IP Rating IP66 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type Screw | ||
Series GLD | ||
Minimum Operating Temperature -40°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 85°C | ||
Width 30.5mm | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Length 68.5mm | ||
Depth 26.35mm | ||
Hazardous Area Certification No | ||
Operating Force 0.12N | ||
Mechanical Life 10000000Cycles | ||
Conduit Entry PG13.5 | ||
- Pays d'origine :
- GB

Honeywell GLD Series Limit Switch, IP66, 6A Switching Current - GLDB01A4J
Features and Benefits:
• Fibreglass-reinforced thermoplastic housing increases chemical resistance
• Snap-action contacts deliver quick, reliable switching response
• 1NC/1NO contact arrangement enables versatile control logic
• Supports 240V AC switching at 6A for mains control circuits
• Mechanical life of 10,000,000 cycles minimises maintenance intervals
Applications
• Ideal for safety interlock feedback on access panels
• Used with motor starters for limit sensing in hoists and winches
• Can be used for position sensing in packaging machinery
• Used for status feedback in automated assembly stations
What temperature range can it operate within?
How are electrical connections made?
Which approvals support installation in regulated installations?
What type of actuation force is required to operate the switch?
How does contact switching perform on DC supplies?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell GLD Series Plunger Limit Switch IP66 240V ac, 6A
- Honeywell GLD Series Roller Plunger Limit Switch IP66 240V ac, 6A
- Honeywell GLD Series Roller Lever Limit Switch IP66 240V ac, 6A
- Honeywell GLD Series Metal Roller Limit Switch IP66 240V ac, 6A
- Honeywell GLD Series Coil Spring Limit Switch IP66 240V ac, 6A
- Honeywell GLD Series Plunger Limit Switch IP66 240V ac, 10A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch IP66 240V