Honeywell Technologies SSCSNBN002NDAA5 Piezoresistive Pressure SensorThrough Hole 8 SIP

Sous-total (1 boîte de 50 unités)*

3 262,85 €

(TVA exclue)

3 948,05 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Temporairement en rupture de stock
  • Expédition à partir du 08 décembre 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
La Boite*
50 +65,257 €3 262,85 €

*Prix donné à titre indicatif

N° de stock RS:
226-9809
Référence fabricant:
SSCSNBN002NDAA5
Fabricant:
Honeywell
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Honeywell

Maximum Overload Pressure

2.64kPa

Product Type

Piezoresistive Pressure Sensor

Sensor Type

Piezoresistive Pressure Sensor

Mount Type

Through Hole

Package Type

SIP

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

0.02 kPa

Maximum Supply Voltage

5V

Accuracy

±0.25 %

Port Type

Dual Axial

Maximum Operating Temperature

85°C

Length

27.31mm

Height

22.87mm

Standards/Approvals

No

Series

SSC

Minimum Operating Pressure

-2in/H2O

Minimum Operating Temperature

-40°C

Automotive Standard

No

Honeywell SSC Series Piezoresistive Pressure Sensor, ±0.25% Accuracy -2in/H2O Minimum Operating Pressure - SSCSNBN002NDAA5


This piezoresistive pressure sensor converts small differential pressure into an electrical signal for low-pressure measurement tasks. It operates from low-voltage supplies and is intended for applications requiring precise monitoring within a limited pressure range, functioning reliably across a wide ambient temperature range.

Features and Benefits:


• Operates from 3.3V supply for low-voltage system compatibility
• Measures -2 inH2O to 0.02kPa for very low-pressure detection
• Accuracy ±0.25% for tight measurement tolerances
• Through-hole SIP package for straightforward board mounting
• Withstands -40°C to 85°C for harsh temperature operation

Applications


• Suitable for HVAC airflow sensing in control systems
• Ideal for medical low-pressure monitoring equipment
• Used with laboratory gas-flow calibration rigs
• Can be used for environmental monitoring stations
• Suitable for industrial pneumatic leak detection

What electrical supply limits should I observe?


The device requires at least 3.3V and must not exceed 5V supply.

How many electrical connections are available on the module?


The unit provides eight pins to accommodate signal and power routing.

What mechanical mounting method does it use?


It is designed for through-hole mounting in a single-in-line package format.

What port arrangement does the sensor employ for pressure input?


The sensor features dual axial ports to accept differential or reference lines.

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail

Les données personnelles que vous nous fournissez en vous inscrivant à cette liste de diffusion seront traitées conformément à notre politique de confidentialité.