Honeywell Technologies Pressure SensorBoard 8 SMT

Sous-total (1 boîte de 50 unités)*

4 391,85 €

(TVA exclue)

5 314,15 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • 50 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
La Boite*
50 +87,837 €4 391,85 €

*Prix donné à titre indicatif

N° de stock RS:
226-9687
Référence fabricant:
HSCMRRN001ND2A3
Fabricant:
Honeywell
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Honeywell

Maximum Overload Pressure

2.64kPa

Product Type

Pressure Sensor

Sensor Type

Piezoresistive Pressure Sensor

Mount Type

Board

Package Type

SMT

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

0.01 kPa

Port Type

Dual Radial Barbed

Accuracy

±0.25 %

Maximum Supply Voltage

5V

Maximum Operating Temperature

+85°C

Length

10mm

Height

13.75mm

Standards/Approvals

ISO 9001

Series

HSC

Width

13.3mm

Minimum Operating Pressure

-1in/H2O

Minimum Operating Temperature

-20°C

Automotive Standard

ISO 9001

Honeywell HSC Series Piezoresistive Pressure Sensor, ±0.25% Accuracy, 3.3V Minimum Supply Voltage - HSCMRRN001ND2A3


This pressure sensor is a Compact board-mounted device that measures absolute, gauge or differential pressures in non‑corrosive gases and selected non‑ionic liquids. It is a piezoresistive device with on‑board signal conditioning providing ratiometric analogue or digital output for Rapid pressure readings across its compensated temperature span. The product is suitable for surface‑mount assembly and accepts dual radial barbed connections for fluid interfacing in demanding systems.

Features and Benefits:


• ±0.25% FSS BFSL accuracy reduces software correction needs
• Calibrated and temperature compensated for 0°C to 50°C operation
• Ratiometric analogue or 14‑bit digital output for direct microprocessor interfacing
• Low power consumption under 10 mW supports battery operation
• Fast response with analogue ∼1 MS and digital ∼0.46 MS update rates
• Dual radial barbed port option simplifies tubing connections

Applications


• Suitable for airflow monitoring and respiratory equipment
• Ideal for HVAC filter clog detection and VAV control
• Used with gas flow instrumentation and chromatography systems
• Can be used for ventilators and oxygen concentrators
• Used for pressure calibration and flow calibrators

What output formats are available?


It provides a ratiometric analogue output and 12-14 bit digital output compatible with I2C or SPI interfaces.

How is temperature influence handled?


Internal calibration and temperature compensation correct offset, sensitivity and non-linearity over the compensated range.

What media can be measured?


It is intended for non-corrosive, non-ionic gases and optionally compatible non-ionic liquids for ranges above 40 mbar.

What protection exists for solder reflow?


The device meets IPC/JEDEC J-STD-020E moisture sensitivity level 1 and tolerates standard reflow profiles.