Honeywell GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A
- N° de stock RS:
- 311-2465
- Numéro d'article Distrelec:
- 303-44-316
- Référence fabricant:
- GLAB20B
- Fabricant:
- Honeywell
Sous-total (1 unité)*
328,93 €
(TVA exclue)
398,01 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 16 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Unité | Prix par unité |
|---|---|
| 1 + | 328,93 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 311-2465
- Numéro d'article Distrelec:
- 303-44-316
- Référence fabricant:
- GLAB20B
- Fabricant:
- Honeywell
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| Contact Configuration | DPDT | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | Screw | |
| Series | GLA | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Depth | 42mm | |
| Length | 145.8mm | |
| Width | 42mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.33Nm | |
| Conduit Entry | Threaded conduit | |
| Mechanical Life | 15000000Cycles | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
Contact Configuration DPDT | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type Screw | ||
Series GLA | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Depth 42mm | ||
Length 145.8mm | ||
Width 42mm | ||
Hazardous Area Certification No | ||
Operating Force 0.33Nm | ||
Conduit Entry Threaded conduit | ||
Mechanical Life 15000000Cycles | ||
- Pays d'origine :
- GB

Honeywell GLA Series Limit Switch, 145.8mm Length, IP67 - GLAB20B
Features and Benefits:
• Rated switching up to 600V AC and 250V DC for high‑voltage tasks
• Switching current capacity of 6A supports control and signalling loads
• Mechanical life of 15 million cycles minimises replacement frequency
• Operating range from −25 °C to 85 °C enables varied ambient use
• IP67 die‑cast zinc housing provides ingress protection and robustness
Applications
• Ideal for actuating safety interlocks on industrial doors
• Used with motor control systems for limit position sensing
• Can be used for machine‑tool Axis homing and overtravel protection
• Suitable for heavy‑duty packaging equipment position monitoring
What type of actuator does it use and how does that affect contact operation?
How is the unit protected against dust and water ingress during washdown or outdoor use?
Which approvals cover safety and conformity for industrial integration?
How is electrical wiring accommodated on‑site?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Plunger Limit Switch IP67 600V ac, 10A
- Honeywell GLA Series Rod Limit Switch IP67 600V ac, 6A