Honeywell GLA Series Plunger Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600V ac
- N° de stock RS:
- 240-2509
- Référence fabricant:
- GLAC07C
- Fabricant:
- Honeywell
Sous-total (1 unité)*
288,42 €
(TVA exclue)
348,99 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
En stock
- 21 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 288,42 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 240-2509
- Référence fabricant:
- GLAC07C
- Fabricant:
- Honeywell
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Length | 145.8mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Width | 42mm | |
| Depth | 42mm | |
| Hazardous Area Certification | NO | |
| Conduit Entry | 20 mm | |
| Operating Force | 16N | |
| Mechanical Life | 15000000Cycles | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Length 145.8mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Width 42mm | ||
Depth 42mm | ||
Hazardous Area Certification NO | ||
Conduit Entry 20 mm | ||
Operating Force 16N | ||
Mechanical Life 15000000Cycles | ||

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, 1 NO/1 NC Contact Configuration - GLAC07C
This limit switch is a mechanically operated plunger device designed to detect and interrupt motion in industrial systems. Built for demanding environments, it provides snap‑action contact switching with both normally open and normally closed outputs and is suitable for use where robust electrical isolation and environmental protection are required.
Features and Benefits:
• IP67 enclosure ensures protection against dust and temporary immersion
• Snap‑action contacts handle up to 600V AC switching
• Two‑contact arrangement provides one NO and one NC contact
• Die‑cast zinc housing offers impact resistance and long service life
• Operating force of 16 N allows precise actuation response
• Mechanical endurance rated for 15 million cycles for extended operation
• Snap‑action contacts handle up to 600V AC switching
• Two‑contact arrangement provides one NO and one NC contact
• Die‑cast zinc housing offers impact resistance and long service life
• Operating force of 16 N allows precise actuation response
• Mechanical endurance rated for 15 million cycles for extended operation
Applications
• Suitable for end‑of‑travel detection on automated conveyors
• Ideal for position sensing on industrial presses and machines
• Used with control panels requiring M20 conduit entry connections
• Can be used for safety interlocks in manufacturing cells
• Used for limit sensing in material‑handling equipment
• Ideal for position sensing on industrial presses and machines
• Used with control panels requiring M20 conduit entry connections
• Can be used for safety interlocks in manufacturing cells
• Used for limit sensing in material‑handling equipment
What temperature range can it operate within?
It functions across a temperature span from −25 °C up to 85 °C, enabling use in many indoor and sheltered outdoor installations.
How is the electrical connection provided?
The unit accepts conduit via an M20 entry and offers screw‑type terminals for wiring the NO and NC contacts.
What standards does the device meet for acceptance in installations?
It is supplied with approvals from UL, CSA, CE and CCC to facilitate integration in regulated environments.
What is the expected mechanical lifespan under normal operation?
The switch is specified to withstand 15 million mechanical cycles, supporting high‑duty industrial applications.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell GLA Series Plunger Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch IP67 600 V ac, 6 A
- Honeywell GLA Series Plunger Limit Switch IP67 600 V ac, 6 A
- Honeywell Plunger Limit Switch IP67, Die Cast Zinc Housing
- Honeywell GLA Series Roller Plunger Limit Switch IP67 600 V ac, 10 A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67, Die Cast Zinc Housing
- Honeywell Plunger Limit Switch IP66 IP68, Die Cast Zinc Housing
- Honeywell BZE6 Series Plunger Limit Switch IP40, Die Cast Zinc Housing
