Honeywell Technologies GLA Series Plunger Limit Switch, 1 NO/1 NC (SPDT), IP67, Die Cast Zinc Epoxy Coated Housing, 600V
- N° de stock RS:
- 311-2358
- Numéro d'article Distrelec:
- 301-38-712
- Référence fabricant:
- GLAB01B
- Fabricant:
- Honeywell Technologies
Sous-total (1 unité)*
217,10 €
(TVA exclue)
262,69 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 1 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
- Plus 10 unité(s) expédiée(s) à partir du 28 décembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 217,10 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 311-2358
- Numéro d'article Distrelec:
- 301-38-712
- Référence fabricant:
- GLAB01B
- Fabricant:
- Honeywell Technologies
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell Technologies | |
| Actuator Type | Plunger | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NO/1 NC (SPDT) | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | Screw | |
| Series | GLA | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Length | 145.8mm | |
| Depth | 42mm | |
| Width | 42mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Hazardous Area Certification | No | |
| Operating Force | 9.5N | |
| Mechanical Life | 15000000Cycles | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell Technologies | ||
Actuator Type Plunger | ||
Product Type Limit Switch | ||
Contact Configuration 1 NO/1 NC (SPDT) | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type Screw | ||
Series GLA | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Length 145.8mm | ||
Depth 42mm | ||
Width 42mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Hazardous Area Certification No | ||
Operating Force 9.5N | ||
Mechanical Life 15000000Cycles | ||
- Pays d'origine :
- GB

Honeywell GLA Series Limit Switch, 145.8mm Length, IP67 - GLAB01B
Features and Benefits:
• Single-pole double-throw contact reduces wiring complexity
• IP67 sealed housing for use in wet or dusty conditions
• Die-cast zinc case for strong impact resistance
• Rated for switching up to 600V and 6A for heavy electrical loads
• Mechanical endurance of 15 million cycles minimises replacement frequency
Applications
• Ideal for limit detection on industrial valves and actuators
• Used with safety interlocks on machinery access panels
• Can be used for end-of-travel detection on material handling equipment
What actuator style does it use and how does that affect mounting?
How does the contact arrangement support control logic?
Which environmental conditions can it withstand?
What temperature extremes are acceptable for operation?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac
- Honeywell Technologies GLA Series Roller Plunger Limit Switch IP67 600V
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac,
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V