Testo Saveris 2-H1 Data Logger, USB
- N° de stock RS:
- 876-5499
- Référence fabricant:
- 0572 2004
- Fabricant:
- Testo
Produit de remplacement
Ce produit n'est pas disponible actuellement. Voici notre produit de remplacement:
la pièce
348,00 €
(TVA exclue)
421,08 €
(TVA incluse)
- N° de stock RS:
- 876-5499
- Référence fabricant:
- 0572 2004
- Fabricant:
- Testo
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Testo | |
| Model Number | Saveris 2-H1 | |
| Sensor Type | NTC | |
| Measurement Parameters | Humidity, Temperature | |
| Interface Type | USB | |
| Maximum Temperature Measurement | +50 °C | |
| Power Source | Battery | |
| Best Temperature Measurement Accuracy | ±0.5 % | |
| IP Rating | IP30 | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | +50°C | |
| Display Type | LCD | |
| Alarm | Yes | |
| Battery Type | 4 x AA AlMn | |
| Temperature Measurement Resolution | 0.1% | |
| Maximum Humidity Measurement | 100%RH | |
| Battery Life | 24 month | |
| Includes | Battery, Calibration Protocol, USB Cable, Wall Bracket | |
| Humidity Measurement Resolution | 0.1%RH | |
| Number of Readings Per Channel | 10000 | |
| Dimensions | 95 x 75 x 30.5mm | |
| Best Humidity Measurement Accuracy | ±2 %RH | |
| Sélectionner tout | ||
|---|---|---|
Marque Testo | ||
Model Number Saveris 2-H1 | ||
Sensor Type NTC | ||
Measurement Parameters Humidity, Temperature | ||
Interface Type USB | ||
Maximum Temperature Measurement +50 °C | ||
Power Source Battery | ||
Best Temperature Measurement Accuracy ±0.5 % | ||
IP Rating IP30 | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature +50°C | ||
Display Type LCD | ||
Alarm Yes | ||
Battery Type 4 x AA AlMn | ||
Temperature Measurement Resolution 0.1% | ||
Maximum Humidity Measurement 100%RH | ||
Battery Life 24 month | ||
Includes Battery, Calibration Protocol, USB Cable, Wall Bracket | ||
Humidity Measurement Resolution 0.1%RH | ||
Number of Readings Per Channel 10000 | ||
Dimensions 95 x 75 x 30.5mm | ||
Best Humidity Measurement Accuracy ±2 %RH | ||
Statut RoHS : Exempté
- Pays d'origine :
- CN
testo Saveris 2 WiFi Data Loggers
All measurement data always available, anywhere, on any instrument
Alarms when limit values are violated (by email as standard or by SMS, depending on choice of Cloud license)
testo Saveris 2-T1 and -T2 DIN EN 12830 compliant
Note
Supplied with
Liens connexes
- Testo Saveris 2-T3 Data Logger, USB
- Testo Saveris 2-T1 Data Logger, USB
- Testo Saveris 2-H2 Data Logger, USB
- Testo Saveris 2-T2 Data Logger, USB
- Testo Saveris 2 H1 Temperature & Humidity Data Logger 2 Input Channel(s)
- Testo 184-H1 Temperature Data Logger 2 Input Channel(s)
- Testo TESTO SAVERIS 2-T2 Temperature & Humidity Data Logger, USB / WiFi
- Testo 175-H1 Temperature & Humidity Data Logger 2 Input Channel(s)