Seneca RC150 Series Current Transformer
- N° de stock RS:
- 288-3601
- Numéro d'article Distrelec:
- 300-97-898
- Référence fabricant:
- RC150-025-100-300
- Fabricant:
- Seneca
Actuellement indisponible
Nous ne savons pas si cet article sera de nouveau disponible. RS a l'intention de le retirer de son assortiment sous peu.
- N° de stock RS:
- 288-3601
- Numéro d'article Distrelec:
- 300-97-898
- Référence fabricant:
- RC150-025-100-300
- Fabricant:
- Seneca
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Seneca | |
| Product Type | Current Transformer | |
| Series | RC150 | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | CE, EN61010-2-032, EN61010-2-031, EN61010-1, EN61010-031 | |
| Maximum Operating Frequency | 20kHz | |
| Sélectionner tout | ||
|---|---|---|
Marque Seneca | ||
Product Type Current Transformer | ||
Series RC150 | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals CE, EN61010-2-032, EN61010-2-031, EN61010-1, EN61010-031 | ||
Maximum Operating Frequency 20kHz | ||
- Pays d'origine :
- IT
The Rogowski Coil is a flexible current transducer based on Rogowski principle, designed for accurate measurement in combination with portable devices. It offers a high linearity and wide dynamic range, making it suitable for measuring currents from mA to hundreds of kA. With its non-intrusive design and shielded protection, it is a reliable solution for power monitoring and control systems, harmonics monitoring, and very high current monitoring.
Suitable for measuring currents from mA to hundreds of kA
High linearity and wide dynamic range
Non-intrusive transducer with no power drawn from the main circuit
Flexible design allows for measurements on large or awkward shaped conductors
Totally shielded for stable measurements
Output signal with low voltage, no danger from open-circuited secondary
Wide frequency response suitable for harmonic content and transients monitoring
Available in different sizes for various applications
Liens connexes
- Seneca RC150 Series Current Transformer
- Seneca T201 Series DIN Rail Mounted Current Transformer 4 → 20 mA Output, 6 → 100 V
- Seneca T201DCH300-LP, Current Sensor
- Seneca T201 Series Current Sensor 6 → 100 V dc
- Seneca T201 Series DIN Rail Mounted Current Transformer 4 → 20 mA Output, 12 → 28 V dc
- Seneca T201 Series DIN Rail Mounted Current Transformer 4 → 20 mA Output, 9 → 28 V dc
- Sifam Tinsley ESCT-RC Series Rogowski Coil Current Transformer 150mm Bore, 600 V
- Seneca K109 Series Signal Conditioner Current 30V Supply