Schneider Electric, LRD Thermal Overload Relay 1 NO/1 NC, Trip Dial: 30 → 40 A, 30A, 40 A F.L.C, 40A Contact Rating, 22
- N° de stock RS:
- 727-6210
- Référence fabricant:
- LRD340
- Fabricant:
- Schneider Electric
Sous-total (1 unité)*
109,99 €
(TVA exclue)
133,09 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- Plus 21 unité(s) expédiée(s) à partir du 23 novembre 2026
- Plus 57 unité(s) expédiée(s) à partir du 23 novembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 109,99 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 727-6210
- Référence fabricant:
- LRD340
- Fabricant:
- Schneider Electric
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Schneider Electric | |
| Product Type | Thermal Overload Relay | |
| FLC Motor Rating | 30A, 40A | |
| Relay Contact Current | 40A | |
| Series | LRD | |
| Mount Type | Under Contactor Mount | |
| Power Rating | 22kW | |
| Pole and Throw Configuration | 3 | |
| Terminal Type | Screw | |
| Normal State Configuration | 1 NO/1 NC | |
| Reset Method | Push Button | |
| IP Rating | IP20 | |
| Minimum Operating Temperature | -20°C | |
| Width | 55mm | |
| Adjustable Current Range | 30 → 40 A | |
| Number of Auxiliary Contacts | 2 | |
| Length | 70mm | |
| Contact Voltage | 1kV ac | |
| Maximum Operating Temperature | 60°C | |
| Depth | 116mm | |
| Standards/Approvals | UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | |
| Supply Voltage | 690V | |
| Sélectionner tout | ||
|---|---|---|
Marque Schneider Electric | ||
Product Type Thermal Overload Relay | ||
FLC Motor Rating 30A, 40A | ||
Relay Contact Current 40A | ||
Series LRD | ||
Mount Type Under Contactor Mount | ||
Power Rating 22kW | ||
Pole and Throw Configuration 3 | ||
Terminal Type Screw | ||
Normal State Configuration 1 NO/1 NC | ||
Reset Method Push Button | ||
IP Rating IP20 | ||
Minimum Operating Temperature -20°C | ||
Width 55mm | ||
Adjustable Current Range 30 → 40 A | ||
Number of Auxiliary Contacts 2 | ||
Length 70mm | ||
Contact Voltage 1kV ac | ||
Maximum Operating Temperature 60°C | ||
Depth 116mm | ||
Standards/Approvals UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, UL 60947-4-1 | ||
Supply Voltage 690V | ||
- Pays d'origine :
- FR
Schneider Electric LRD Series Thermal Overload Relay, 30 to 40 A Motor Rating, Automatic Reset Method - LRD340
Features & Benefits
Applications
What is the significance of the 30 to 40A adjustment range?
How does the automatic reset function work?
Can it be used with different types of networks?
What type of terminals does this device feature?
What is the impact of the rated operational voltage?
Standards
Liens connexes
- Schneider Electric Trip Dial: 30 → 40 A 40 A F.L.C
- Schneider Electric Trip Dial: 30 → 38 A 38 A F.L.C
- Schneider Electric Trip Dial: 30 → 40 A 40 A F.L.C 22 kW 3
- Schneider Electric Trip Dial: 0.25 → 0.4 A 400 mA F.L.C, 400mA Contact
- Schneider Electric Trip Dial: 0.4 → 0.63 A 630 mA F.L.C
- Schneider Electric Trip Dial: 0.16 → 0.25 A 250 mA F.L.C
- Schneider Electric Trip Dial: 17 → 25 A 25 A F.L.C, 25A Contact Rating
- Schneider Electric Trip Dial: 0.1 → 0.16 A 160 mA F.L.C 60
