Omron H5CC Series Flush Timer Relay, 1-Contact, 100 to 240 V dc 100V ac, 240 V ac, 0.001 s to 999999h h, 2-Function,

Sous-total (1 unité)*

226,40 €

(TVA exclue)

273,94 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Temporairement en rupture de stock
  • Expédition à partir du 28 septembre 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +226,40 €

*Prix donné à titre indicatif

N° de stock RS:
402-684
Référence fabricant:
H5CC-A11S
Fabricant:
Omron
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Omron

Product Type

Timer Relay

Function

Multifunction

Mount Type

Flush

Time Range

0.001 s to 999999h h

Number of Contacts

1

Number of Timer Functions

2

Switching Voltage

250V

Contact Configuration

SPDT

IP Rating

IP66

Timing Adjustment

Polar

Supply DC Voltage

100 to 240 V dc

Minimum Operating Temperature

-10°C

Contact Current

5A

Supply AC Voltage

100, 240V ac

Maximum Operating Temperature

55°C

Terminal Type

Plug-In

Height

48mm

Length

63.7mm

Standards/Approvals

EN61812-1, UKCA, UL508, RCM, CSA C22.2 No. 14, CCC GB/T 14048.5, VDE0106/P100

Width

48mm

Series

H5CC

Pays d'origine :
CN

Omron H5CC Series Timer Relay, 0.001s to 999999h Time Range, IP66 Rating - H5CC-A11S


This timer relay is a Compact control device designed for timing functions in industrial control panels and automation systems. It combines selectable time operation modes with single-pole changeover switching to manage sequences and delays in electrical circuits. The unit is intended for flush mounting and connects via a removable Terminal Block for straightforward serviceability.

Features and Benefits:


• SPDT contact rated 5A for switching moderate loads • Time range from 0.001s to 999999h for extreme flexibility • Accepts 100-240V AC or 100-240V DC supply for universal installation • Switching capability up to 250V to handle typical control voltages • Polar timing adjustment for precise setpoint tuning • IP66 enclosure rating for protection against dust and powerful water jets

Applications


• Suitable for sequencing starters in motor control cabinets • Ideal for timing interlocks on conveyor systems • Used for delayed switching in lighting and signalling circuits • Can be used for automation timing in testing rigs • Suitable for control logic in HVAC and process panels

How is the device mounted and connected within a panel?


It is designed for flush mounting and uses a plug-in Terminal Block to allow quick insertion and removal without rewiring.

Which environment limits should be observed during installation?


The relay is intended for use within an operating temperature band from -10°C to 55°C and its IP66 rating means it tolerates dust ingress and powerful water jets but not continuous immersion.

How many independent timer functions are available for selection?


The unit provides two selectable timing functions to cover different delay and sequence requirements.

What approvals support deployment in regulated installations?


It carries multiple standards and approvals including EN61812-1, UKCA, UL508, RCM, CSA C22.2 No.14, CCC GB/T14048.5 and VDE0106/P100.

What are the physical connection and footprint considerations for panel design?


The relay has a plug-in Terminal Interface and a Compact footprint measuring 48mm in width and 63.7mm in length to aid dense mounting layouts.