SICK MOC3ZA Series Safety Controller, 24 V dc
- N° de stock RS:
- 285-8879
- Référence fabricant:
- MOC3ZA-KAZ33D3
- Fabricant:
- SICK
Sous-total (1 unité)*
645,84 €
(TVA exclue)
781,47 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
En stock
- Plus 2 unité(s) expédiée(s) à partir du 08 décembre 2025
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 645,84 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 285-8879
- Référence fabricant:
- MOC3ZA-KAZ33D3
- Fabricant:
- SICK
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | SICK | |
| Series | MOC3ZA | |
| Safety Category | 4 | |
| SIL | SIL 3 | |
| Supply Voltage | 24 V dc | |
| Terminal Type | Screw Terminal | |
| IP Rating | IP20, IP40 | |
| Length | 112mm | |
| Depth | 121mm | |
| Dimensions | 45 x 112 x 121 mm | |
| Width | 45mm | |
| Sélectionner tout | ||
|---|---|---|
Marque SICK | ||
Series MOC3ZA | ||
Safety Category 4 | ||
SIL SIL 3 | ||
Supply Voltage 24 V dc | ||
Terminal Type Screw Terminal | ||
IP Rating IP20, IP40 | ||
Length 112mm | ||
Depth 121mm | ||
Dimensions 45 x 112 x 121 mm | ||
Width 45mm | ||
- Pays d'origine :
- DE
Overview
The Standstill Monitor MOC3ZA is a safety device for machine drives and serves to protect against dangerous movements. It also measures the residual voltage meaning that no additional sensors are required for the purpose of standstill monitoring. This ren
The positively guided safety contacts enable the device to be connected to all of SICK's safe control solutions.
At a glance
Standstill monitoring by means of residual voltage measurement
3 normally open and 1 normally closed positively guided safety contacts
2 application diagnostic outputs for semiconductors
1 application diagnostic output normally open
PL e (EN ISO 13849), S
3 normally open and 1 normally closed positively guided safety contacts
2 application diagnostic outputs for semiconductors
1 application diagnostic output normally open
PL e (EN ISO 13849), S
Your Benefit
Quick mounting and installation thanks to the lack of additional wiring requirements
Simple commissioning with a screwdriver
Easy to retrofit as the subsequent mounting of sensors is not necessary
Simple commissioning with a screwdriver
Easy to retrofit as the subsequent mounting of sensors is not necessary
Applications
Note
Liens connexes
- SICK MOC3ZA Series Safety Controller 24 V
- SICK MOC3ZA Series Safety Controller 230 V
- SICK UE410 Series Safety Controller, 24 V dc
- SICK FX3 Series Safety Controller, 24 V dc
- SICK FXL1 Series Safety Controller 24 V dc
- SICK MOC3SA Series Safety Controller, 24 V
- SICK UE410 Series Safety Controller 1 Safety Outputs, 24 V dc
- SICK UE410 Series Safety Controller 4 Safety Outputs, 24 V dc