Eaton RCBO, 20A Current Rating, 1P+N Poles, 30mA Trip Sensitivity, Type B, PXK Range
- N° de stock RS:
- 183-3541
- Référence fabricant:
- 236949 PXK-B20/1N/003-A
- Fabricant:
- Eaton
Sous-total (1 unité)*
166,45 €
(TVA exclue)
201,40 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
En stock
- 16 unité(s) prête(s) à être expédiée(s)
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 166,45 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 183-3541
- Référence fabricant:
- 236949 PXK-B20/1N/003-A
- Fabricant:
- Eaton
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Eaton | |
| Current Rating | 20A | |
| Number of Poles | 1P+N | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Range | PXK | |
| Circuit Breaker Type | RCD | |
| Rated AC Voltage | 240V | |
| Earth Leakage Protection Type | A | |
| Break Time | Instantaneous | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Application | Commercial, Residential | |
| Sélectionner tout | ||
|---|---|---|
Marque Eaton | ||
Current Rating 20A | ||
Number of Poles 1P+N | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Range PXK | ||
Circuit Breaker Type RCD | ||
Rated AC Voltage 240V | ||
Earth Leakage Protection Type A | ||
Break Time Instantaneous | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Application Commercial, Residential | ||
- Pays d'origine :
- AT
Eaton Residual Current Circuit Breaker With Overcurrent Protection, 1+N Poles - PXK-B Series - PXK-B20/1N/003-A
This RCBO (residual current breaker with overcurrent protection) from Eaton effectively monitors the current flow in your electrical systems. It automatically initiates a disconnection if an overcurrent or earth leakage is detected, stopping any damage to equipment and preventing electrocution. Its type-B tripping characteristic means it's designed to trip at fault currents three to five times the rated current of 20A – so between 60A and 100A. Mount this unit in power control setups for household electrical systems, medical devices and charging stations.
• 10kA breaking capacity makes for reliable operations under pressure
• Rated IP20 (ingress protection) so it's touch-proof and protected from dust
• Operating temperature range between -25°C and +40°C for use in demanding industrial environments
• Rated IP20 (ingress protection) so it's touch-proof and protected from dust
• Operating temperature range between -25°C and +40°C for use in demanding industrial environments
What does the earth leakage protection in this RCBO mean?
An earth leakage refers to an abnormal flowing current that may interact with the metal component of an electrical device, which can result in electrocution. This RCBO monitors the flow of current and detects when leakage has occurred, automatically shutting off. This switchgear detects leakage current of up to 20A and initiates tripping instantaneously.
Note
Eaton formerly known as Moeller
Liens connexes
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P + N Poles Type B, xPole Range