Eaton AFDD, 10A Current Rating, 2P Poles, 30mA Trip Sensitivity, Type B, AFDD+ Range
- N° de stock RS:
- 146-2816
- Référence fabricant:
- 187168 AFDD-10/2/B/003-A
- Fabricant:
- Eaton
Sous-total (1 unité)*
238,35 €
(TVA exclue)
288,40 €
(TVA incluse)
Informations sur le stock actuellement non accessibles
Unité | Prix par unité |
|---|---|
| 1 + | 238,35 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 146-2816
- Référence fabricant:
- 187168 AFDD-10/2/B/003-A
- Fabricant:
- Eaton
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Eaton | |
| Current Rating | 10A | |
| Range | AFDD+ | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Circuit Breaker Type | AFDD | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 240V | |
| Mounting Style | DIN Rail Mount | |
| Earth Leakage Protection Type | AC | |
| Overall Length | 54mm | |
| Reset Actuator Type | Toggle Switch | |
| Overall Dimensions | 54 x 70 x 80mm | |
| Application | Commercial, Residential | |
| Break Time | Instantaneous | |
| Terminal Contact Type | Screw | |
| Overall Width | 80mm | |
| Overall Depth | 70mm | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Sélectionner tout | ||
|---|---|---|
Marque Eaton | ||
Current Rating 10A | ||
Range AFDD+ | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Circuit Breaker Type AFDD | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 240V | ||
Mounting Style DIN Rail Mount | ||
Earth Leakage Protection Type AC | ||
Overall Length 54mm | ||
Reset Actuator Type Toggle Switch | ||
Overall Dimensions 54 x 70 x 80mm | ||
Application Commercial, Residential | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Overall Width 80mm | ||
Overall Depth 70mm | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
- Pays d'origine :
- CZ
Type A & B Switch Disconnector
Professional range of Eaton Memshield incomer switch disconnectors for Type A and B distribution boards. The switch disconnectors are designed for general commercial building applications.
Eaton Arc Fault Detection Device, 2 Pole, Type B - AFDD+ Series - AFDD-10/2/B/003-A
This AFDD (arc fault detection device) from Eaton breaks circuits when it detects electrical arcs or high-power discharges of electricity between two conductors. These faults are typically caused by loose or damaged wires and terminals, and can generate enough heat to cause a fire. As well as an AFDD, this multi-purpose device functions as an RCD (residual current device) to detect and prevent earth faults, and an MCB (miniature circuit breaker) for short circuit overloads.
• LED fault indicator signals the exact cause of the trip
• Green-to-red coloured switch indicators clearly show when device is on or off
• Yellow tripping test button lets you check switch is operational
• Green-to-red coloured switch indicators clearly show when device is on or off
• Yellow tripping test button lets you check switch is operational
How do I install this device?
Connect the neutral and line wires either way round into the bottom of the device and connect the load wires to the top.
How does the LED indicator work?
The LED side indicator is green in normal operation. When turned back on after a trip, a yellow light flashes between one and six times to indicate the cause. This tells you whether it is one of two series arc faults, a parallel arc fault, overvoltage, overheating or a wider system fault.
Note
Eaton formerly known as Moeller
Memshield
Liens connexes
- Eaton AFDD 2P Poles Type B, AFDD+ Range
- Eaton AFDD 2P Poles Type B, AFDD+ Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type C, Eaton Moeller Range
