Fluke 718 -12psi to 100psi Pressure Calibrator - With RS Calibration
- N° de stock RS:
- 479-6373
- Référence fabricant:
- FLUKE 718 EX 100G
- Fabricant:
- Fluke
Sous-total (1 unité)*
3 454,00 €
(TVA exclue)
4 179,34 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 3 454,00 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 479-6373
- Référence fabricant:
- FLUKE 718 EX 100G
- Fabricant:
- Fluke
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Fluke | |
| Maximum Pressure Measurement | 100psi | |
| Minimum Pressure Measurement | -12psi | |
| Resolution | 0.01 psi | |
| Calibrated | RSCAL | |
| Model Number p | 718 | |
| Intrinsically Safe | Yes | |
| Current Loop Measurement | Yes | |
| Maximum Operating Temperature | +55°C | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Dimensions | 216 x 94 x 66mm | |
| Height | 66mm | |
| Length | 216mm | |
| Hazardous Area Certification | ATEX | |
| Width | 94mm | |
| Sélectionner tout | ||
|---|---|---|
Marque Fluke | ||
Maximum Pressure Measurement 100psi | ||
Minimum Pressure Measurement -12psi | ||
Resolution 0.01 psi | ||
Calibrated RSCAL | ||
Model Number p 718 | ||
Intrinsically Safe Yes | ||
Current Loop Measurement Yes | ||
Maximum Operating Temperature +55°C | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Dimensions 216 x 94 x 66mm | ||
Height 66mm | ||
Length 216mm | ||
Hazardous Area Certification ATEX | ||
Width 94mm | ||
Statut RoHS non applicable
Fluke Pressure Calibrator, 100psi Maximum Pressure Measurement, ±0.05% Accuracy - FLUKE-718EX100
This pressure calibrator is an intrinsically safe, battery-powered handheld instrument designed for pressure and loop current checks in hazardous environments. It integrates a manual pressure/vacuum pump and an internal sensor for precise field measurements, while offering compatibility with intrinsically safe pressure modules for extended ranges.
Features & Benefits
• ±0.05% full-scale pressure measurement for accurate calibration
• 0.01psi resolution enabling fine differential readings
• 0mA–24mA current measurement with 0.001mA resolution for loop checks
• ATEX II 1G Ex ia IIC T4 certification for use in explosive atmospheres
• 20h alkaline battery life for extended field operation
• Built-in vernier pump and bleed valve for controlled pressure application
• 0.01psi resolution enabling fine differential readings
• 0mA–24mA current measurement with 0.001mA resolution for loop checks
• ATEX II 1G Ex ia IIC T4 certification for use in explosive atmospheres
• 20h alkaline battery life for extended field operation
• Built-in vernier pump and bleed valve for controlled pressure application
**Applications**
• Suitable for commissioning and verification of process transmitters in hazardous zones
• Ideal for pressure switch testing and adjustment on site
• Used with intrinsically safe pressure modules to extend measurement to 3000psi
• Can be used for routine loop checks and maintenance of 4–20mA systems
• Ideal for pressure switch testing and adjustment on site
• Used with intrinsically safe pressure modules to extend measurement to 3000psi
• Can be used for routine loop checks and maintenance of 4–20mA systems
What pressure range does it support without additional modules?
The internal sensor covers −12psi to 100psi with specified accuracy and resolution.
How is external module connectivity handled?
Pressure modules attach via a dedicated LEMO connector and the instrument auto-selects the module readout.
What inputs are provided for current and pressure?
Current connects to shrouded banana jacks and pressure uses a 1/8in NPT fitting.
How does temperature affect measurement performance?
Temperature coefficients add up to +0.01% of range per °C outside the 18°C–28°C reference for pressure and specified coefficients for current.
Group and Category
II 2 G EEx ib IIC T4
Supplied with
protective red holster, TL75 test leads, AC72 test clips, media filter, CD instruction manual & content control diagram.
Liens connexes
- Fluke 718 -850mbar to 7bar Pressure Calibrator
- Fluke 718 -850mbar to 2bar Pressure Calibrator - With RS Calibration
- Fluke -850mbar to 2bar 718 Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke Fluke-71X-TRAP Pressure Calibrator 718 Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator