Fluke 787B 787B Handheld Multimeter True RMS, 1 A, 1 A, 1000 V, UKAS Calibrated
- N° de stock RS:
- 136-5149
- Référence fabricant:
- FLUKE-787B
- Fabricant:
- Fluke
Sous-total (1 unité)*
1 761,00 €
(TVA exclue)
2 130,81 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 13 restante(s), prêt à être expédié
- Plus 5 unité(s) expédiée(s) à partir du 10 septembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 1 761,00 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 136-5149
- Référence fabricant:
- FLUKE-787B
- Fabricant:
- Fluke
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Fluke | |
| Product Type | Multimeter | |
| Multimeter Type | Handheld | |
| Model Number | 787B | |
| Resistance Resolution | 100mΩ | |
| Display Type | Digital | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Diode Test, Loop, Resistance | |
| Maximum AC Voltage Measurement | 1000V | |
| Maximum Resistance Measurement | 40mΩ | |
| Maximum AC Current Measurement | 1A | |
| Maximum DC Current Measurement | 1A | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| DC Current Accuracy | ±0.05 % rdg + 2 Digits | |
| AC Current Accuracy | ±1 % rdg + 2 Count | |
| DC Voltage Accuracy | ±0.1 % rdg + 1 Digits | |
| AC Voltage Accuracy | ± 0.7 % + 2 | |
| AC Voltage Resolution | 0.1mV ac | |
| AC Current Resolution | 0.001A ac | |
| DC Current Resolution | 0.001mA dc | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 19.99kHz | |
| Power Source | Battery | |
| Resistance Measurement Accuracy | ±0.2 % rdg + 2 Digits | |
| Minimum Operating Temperature | -20°C | |
| Battery Life | 140h | |
| Maximum Operating Temperature | 55°C | |
| Weight | 600g | |
| Length | 100mm | |
| Width | 50mm | |
| Series | 787B | |
| Height | 203mm | |
| Standards/Approvals | No | |
| Safety Category Level | CAT III, CAT IV | |
| Calibrated | UKAS | |
| Safety Category Voltage | 1000V | |
| Battery Type | AA Alkaline | |
| Sélectionner tout | ||
|---|---|---|
Marque Fluke | ||
Product Type Multimeter | ||
Multimeter Type Handheld | ||
Model Number 787B | ||
Resistance Resolution 100mΩ | ||
Display Type Digital | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Diode Test, Loop, Resistance | ||
Maximum AC Voltage Measurement 1000V | ||
Maximum Resistance Measurement 40mΩ | ||
Maximum AC Current Measurement 1A | ||
Maximum DC Current Measurement 1A | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
DC Current Accuracy ±0.05 % rdg + 2 Digits | ||
AC Current Accuracy ±1 % rdg + 2 Count | ||
DC Voltage Accuracy ±0.1 % rdg + 1 Digits | ||
AC Voltage Accuracy ± 0.7 % + 2 | ||
AC Voltage Resolution 0.1mV ac | ||
AC Current Resolution 0.001A ac | ||
DC Current Resolution 0.001mA dc | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 19.99kHz | ||
Power Source Battery | ||
Resistance Measurement Accuracy ±0.2 % rdg + 2 Digits | ||
Minimum Operating Temperature -20°C | ||
Battery Life 140h | ||
Maximum Operating Temperature 55°C | ||
Weight 600g | ||
Length 100mm | ||
Width 50mm | ||
Series 787B | ||
Height 203mm | ||
Standards/Approvals No | ||
Safety Category Level CAT III, CAT IV | ||
Calibrated UKAS | ||
Safety Category Voltage 1000V | ||
Battery Type AA Alkaline | ||
Statut RoHS : Exempté
- Pays d'origine :
- US
Fluke Multimeter, 19.99kHz Maximum Frequency, 140h Battery Life - FLUKE-787B
Features & Benefits
• AC measurement to 19.99kHz enables AC current 19.99 kHz multimeter capability
• 0.1% DC voltage accuracy supports precise voltage diagnostics
• 140h battery life offers a multimeter with 140h battery life for extended field use
• Internal sourcing of 0–20.000mA drives loops up to 24mA with 24V compliance
• True RMS measurement ensures correct readings on non‑sinusoidal signals
**Applications**
• Ideal for calibrating transmitters and loop-powered instruments
• Used for verifying controller input scaling via simultaneous per cent readouts
• Can be used for frequency checks on signal carriers up to 20kHz
• Used with field devices where limited external loop supply is present
How does it handle sourcing and simulation in a live loop?
What indications and modes assist in signal verification?
How long will batteries last during sourcing compared with measurement?
What safety and environmental tolerances support industrial use?
Supplied with
Liens connexes
- Fluke 787B 787B Handheld Multimeter True RMS 1 A RSCAL Calibrated
- Fluke 787B 787B Handheld Multimeter True RMS 1 A, 1000 V
- Fluke 233 233 Handheld Multimeter True RMS, UKAS Calibrated
- Metrix Handheld Multimeter True RMS, UKAS Calibrated
- Sefram SEFRAM7208 Handheld Multimeter True RMS, UKAS Calibrated
- FLIR DM66 Handheld Multimeter True RMS, UKAS Calibrated
- Fluke 177 Digital Multimeter True RMS, UKAS Calibrated
- Fluke 179 Digital Multimeter True RMS, UKAS Calibrated