Fluke Fluke 710 Loop Calibrator Battery

Sous-total (1 unité)*

3 298,66 €

(TVA exclue)

3 991,38 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stock limité
  • 1 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
  • Plus 1 unité(s) expédiée(s) à partir du 02 avril 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +3 298,66 €

*Prix donné à titre indicatif

N° de stock RS:
181-2322
Référence fabricant:
FLUKE-710
Fabricant:
Fluke
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Fluke

Product Type

Loop Calibrator

Model Number

Fluke 710

Accuracy

±0.01 %

Resolution

1 μA

Battery Type

AAA

Battery Life

40h

Power Source

Battery

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Width

90 mm

Length

150mm

Height

30mm

Weight

300g

Standards/Approvals

No

Hazardous Area Certification

No

Pays d'origine :
CN
Smart Control Valve Testing is now easier than ever:The Fluke 710 Valve Testing Loop Calibrator is designed to enable users to perform quick, easy tests on HART smart control valves. Featuring built-in test procedures and an intuitive user interface, the 710 allows users to quickly and easily perform valve tests, while the valve test quick-check results provide at-a-glance diagnostics help you make maintenance decisions faster than ever. The valve health quick-check results let you know whether your valve is in good, marginal or in bad operating condition so you can quickly decide whether additional maintenance is necessary. Valve testing and HART communication in a precision loop calibrator:With the 710 Valve Testing Loop Calibrator’s built in HART communication function, users can source a 4-20 mA signal to cause the smart control valve to move, while simultaneously interpreting the valve’s HART feedback signal to determine whether the valve is moving to the expected position. In addition to positional information, the measured pressure delivered from the valve’s internal I/P (which moves the valve) can be determined through the HART communication protocol. The 710 has built-in test procedures that automatically increase and change the mA signal while monitoring the HART position and pressure feedback from the control valve, giving you a better overall picture of valve health at the simple push of a button

Key valve testing functions include pre-configured valve signature test, speed test, step test, manual test, and bump/partial stroke test

Key mA loop calibrator functions include mA source, mA simulate, mA read, mA read/loop power, and volts read

ValveTrack™ Software enables upload to a PC for further in-depth analysis of valve measurements that are logged and recorded to memory.