Honeywell Technologies GLC Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 10A
- N° de stock RS:
- 808-3135
- Référence fabricant:
- GLCA01A1B
- Fabricant:
- Honeywell Technologies
Sous-total (1 unité)*
86,40 €
(TVA exclue)
104,54 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 30 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
- Plus 25 unité(s) expédiée(s) à partir du 12 octobre 2026
Unité | Prix par unité |
|---|---|
| 1 - 4 | 86,40 € |
| 5 - 9 | 82,94 € |
| 10 + | 78,62 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 808-3135
- Référence fabricant:
- GLCA01A1B
- Fabricant:
- Honeywell Technologies
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell Technologies | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| IP Rating | IP66 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Series | GLC | |
| Minimum Operating Temperature | -40°C | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | UL, CE, CCC, CSA | |
| Depth | 55mm | |
| Width | 30mm | |
| Length | 30.5mm | |
| Hazardous Area Certification | No | |
| Mounting Orientation | Side | |
| Conduit Entry | 0.5 to 14 NPT | |
| Operating Force | 0.12Nm | |
| Mechanical Life | 15000000Operations | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell Technologies | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
IP Rating IP66 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Series GLC | ||
Minimum Operating Temperature -40°C | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals UL, CE, CCC, CSA | ||
Depth 55mm | ||
Width 30mm | ||
Length 30.5mm | ||
Hazardous Area Certification No | ||
Mounting Orientation Side | ||
Conduit Entry 0.5 to 14 NPT | ||
Operating Force 0.12Nm | ||
Mechanical Life 15000000Operations | ||
Honeywell GLC Series Limit Switch, Roller Lever Actuator, IP66 - GLCA01A1B
Features and Benefits:
• 1NC and 1NO contact arrangement allows flexible circuit configurations
• Rated for 10A switching current for mid-power control loads
• Operates on 240V AC and 250V DC for AC and DC system compatibility
• Mechanical life of 15,000,000 operations reduces maintenance interventions
• Operating torque of 0.12 Nm enables sensitive actuation with low force
Applications
• Ideal for detecting end-of-travel in linear actuators and slide mechanisms
• Used for door and guard monitoring in machine safety interlocks
• Can be used for limit detection in packaging and material handling equipment
• Suitable for retrofit control panel integration requiring robust ingress protection
What conduit options are available for wiring entry?
What mounting orientation is supported for installation?
How does the switch cope with temperature extremes?
What standards approvals does it carry for use in international systems?
What materials provide structural protection for harsh environments?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP67 300V
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP66 240V ac,
- Honeywell Technologies GLC Series Adjustable Roller Lever Limit Switch IP66 600V ac, 10A
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Adjustable Roller Lever Limit Switch IP66 240V ac,
- Honeywell Technologies GLC Series Rotary Lever Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Roller Plunger Limit Switch IP66 240V ac,
- Honeywell Technologies GLC Series Plunger Limit Switch IP66 240V ac, 6A