Honeywell Technologies GLA Series Plunger Limit Switch, 1 NC/1 NO, IP67, Die Cast Zinc Housing, 600V ac, 6A
- N° de stock RS:
- 186-8188
- Numéro d'article Distrelec:
- 303-44-317
- Référence fabricant:
- GLAC01B
- Fabricant:
- Honeywell
Sous-total (1 unité)*
241,65 €
(TVA exclue)
292,40 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 5 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
- Plus 12 unité(s) expédiée(s) à partir du 12 octobre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 241,65 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 186-8188
- Numéro d'article Distrelec:
- 303-44-317
- Référence fabricant:
- GLAC01B
- Fabricant:
- Honeywell
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| Contact Configuration | 1 NC/1 NO | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Terminal Type | M20 | |
| Series | GLA | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Length | 145.8mm | |
| Width | 42mm | |
| Depth | 42mm | |
| Hazardous Area Certification | No | |
| Operating Force | 16N | |
| Mechanical Life | 15000000Operations | |
| Conduit Entry | 20 mm | |
| Sélectionner tout | ||
|---|---|---|
Marque Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
Contact Configuration 1 NC/1 NO | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Terminal Type M20 | ||
Series GLA | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Length 145.8mm | ||
Width 42mm | ||
Depth 42mm | ||
Hazardous Area Certification No | ||
Operating Force 16N | ||
Mechanical Life 15000000Operations | ||
Conduit Entry 20 mm | ||
- Pays d'origine :
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, IP67 - GLAC01B
Features and Benefits:
• Snap-action contacts deliver quick, reliable switching at load
• 600V AC switching capability supports high-voltage control circuits
• 6A current rating handles moderate control and signalling loads
• Operating temperature range down to -25°C and up to 85°C allows wide thermal use
• Mechanical endurance rated at 15,000,000 operations reduces maintenance frequency
Applications
• Ideal for machine tool limit sensing in metalworking facilities
• Used with motor starters for safety interlock feedback
• Can be used for position feedback in packaging equipment
• Suitable for gate and barrier open/close monitoring in access control
What conduit connection does it accept for wiring?
How are the electrical terminals configured?
What material protects the housing against corrosion?
Is it certified for recognised safety standards?
What actuation force is required to operate the plunger?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Liens connexes
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A