SICK C2C Series Light Curtain Receiver, 14 mm Resolution

Sous-total (1 unité)*

678,72 €

(TVA exclue)

821,25 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 04 janvier 2027
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +678,72 €

*Prix donné à titre indicatif

N° de stock RS:
285-0953
Référence fabricant:
C2C-EA09010A10000
Fabricant:
SICK
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

SICK

Product Type

Light Curtain

Series

C2C

Beam Resolution

14mm

Component Type

Receiver

Safety Type

2

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V

Minimum Scanning Distance

0μm

Maximum Scanning Distance

10m

Length

150mm

Maximum Response Time

14ms

Width

34mm

Height

32.8mm

Terminal Type

M12 Male Connector

Pays d'origine :
DE

SICK C2C Series Light Curtain, 900mm Protective Height, 14mm Beam Resolution - C2C-EA09010A10000


This light curtain is a receiver device designed for industrial machine safeguarding, providing an optically synchronised safety field to detect interruptions and switch outputs accordingly. It operates in normal industrial environments with a protective field height of 900mm and a maximum scanning distance of 10m, and is supplied with a test rod sized to the device resolution, mounting information and safety instructions.

Features and Benefits:


• 14mm beam resolution for precise object detection
• 14ms response time for Rapid hazard shutdown
• Two PNP OSSD outputs for safe switching behaviour
• Optical synchronisation to prevent interference
• Aluminium housing offering robust mechanical protection

Applications


• Suitable for guarding access to automated presses
• Ideal for integration with safety relays and contactors
• Used with production lines requiring presence detection
• Can be used for perimeter protection on robotic cells

What supply voltage range does it accept?


It runs from 19.2V to 28.8V DC with typical consumption 2.88W.

How are outputs configured and protected?


It provides two PNP semiconductors that are short-circuit protected and cross-circuit monitored.

What environmental conditions can it withstand?


The unit is rated IP65/IP67, operates between -30°C and +55°C and tolerates 15%-95% non‑condensing humidity.

How is the device connected within a control system?


It connects via a 5‑pin M12 plug with a 150mm cable tail and LED status indicators.

Which safety classifications apply to operation?


It is Type 2 to IEC 61496-1, SIL 1 to IEC 61508 and PL c to ISO 13849-1.