Fluke calibration, PRT Probe Handheld 1552A Digital Thermometer, 1 Input(s), 300 °C Max, ±0.05°C Accuracy, RSCAL
- N° de stock RS:
- 735-6672
- Référence fabricant:
- 1552A-12-DL
- Fabricant:
- Fluke calibration
Sous-total (1 unité)*
2 246,50 €
(TVA exclue)
2 718,26 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 2 restante(s), prêt à être expédié
Unité | Prix par unité |
|---|---|
| 1 + | 2 246,50 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 735-6672
- Référence fabricant:
- 1552A-12-DL
- Fabricant:
- Fluke calibration
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Fluke calibration | |
| Maximum Temperature Measurement | 300°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1552A | |
| Thermometer Type | Handheld | |
| Probe Type | PRT | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001 | |
| Battery Life | 300h | |
| Hazardous Area Certification | ATEX | |
| Standards/Approvals | EN 61326:2006 | |
| Width | 57mm | |
| Length | 114mm | |
| Weight | 196g | |
| Height | 25mm | |
| Minimum/Maximum Recordings | Yes | |
| Temperature Scale | °C, F, Fahrenheit | |
| Application | Industrial | |
| Battery Type | 3 x AAA Alkaline | |
| Calibrated | RSCAL | |
| Intrinsically Safe | Yes | |
| Sélectionner tout | ||
|---|---|---|
Marque Fluke calibration | ||
Maximum Temperature Measurement 300°C | ||
Product Type Digital Thermometer | ||
Model Number 1552A | ||
Thermometer Type Handheld | ||
Probe Type PRT | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001 | ||
Battery Life 300h | ||
Hazardous Area Certification ATEX | ||
Standards/Approvals EN 61326:2006 | ||
Width 57mm | ||
Length 114mm | ||
Weight 196g | ||
Height 25mm | ||
Minimum/Maximum Recordings Yes | ||
Temperature Scale °C, F, Fahrenheit | ||
Application Industrial | ||
Battery Type 3 x AAA Alkaline | ||
Calibrated RSCAL | ||
Intrinsically Safe Yes | ||
Non conforme
- Pays d'origine :
- US
Fluke Digital Thermometer, ±0.05°C Accuracy, 300h Battery Life - 1552A-12-DL
Features & Benefits
• Intrinsically safe construction compliant with ATEX/IECEx
• Measures up to 300°C for high‑temperature process checks
• Internal logging option stores up to 10,000 time‑stamped readings
• Three AAA batteries deliver approximately 300 h operation
• Selectable resolution down to 0.001 for fine measurement detail
**Applications**
• Ideal for temperature checks during custody transfer procedures
• Used for verification of food‑processing sensor accuracy
• Can be used for maintenance of heating systems in facilities
• Suitable for on‑site instrument checks in hazardous zones
What sensor type does it use and how does that affect stability?
How is data retrieved and what are the logging interval options?
What operating ambient temperatures will not degrade the readout accuracy?
How does the display assist Rapid field measurements?
Note
Supplied with
Liens connexes
- Fluke calibration 1552A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1552A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - RSCAL
- Fluke calibration 1551A Wired Digital Thermometer 1 Input(s) ±0.05°C Accuracy - UKAS