Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), 160 °C Max, ±0.05°C Accuracy
- N° de stock RS:
- 741-4320
- Référence fabricant:
- 1551A-9-DL
- Fabricant:
- Fluke calibration
Sous-total (1 unité)*
1 480,00 €
(TVA exclue)
1 790,80 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- Prêt à être expédié à partir du 11 février 2027
Unité | Prix par unité |
|---|---|
| 1 + | 1 480,00 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 741-4320
- Référence fabricant:
- 1551A-9-DL
- Fabricant:
- Fluke calibration
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Fluke calibration | |
| Maximum Temperature Measurement | 160°C | |
| Product Type | Digital Thermometer | |
| Model Number | 1551A | |
| Thermometer Type | Handheld | |
| Probe Type | RTD | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Data Storage | Yes | |
| Power Source | Battery | |
| Resolutions Supported | 0.001°C | |
| Battery Life | 300h | |
| Length | 114mm | |
| Height | 25mm | |
| Width | 57mm | |
| Standards/Approvals | EN 61326:2006 | |
| Hazardous Area Certification | ATEX | |
| Weight | 196g | |
| Minimum/Maximum Recordings | Yes | |
| Application | Industrial | |
| Temperature Scale | °C, Fahrenheit, F | |
| Intrinsically Safe | Yes | |
| Battery Type | 3 x AAA Alkaline | |
| Sélectionner tout | ||
|---|---|---|
Marque Fluke calibration | ||
Maximum Temperature Measurement 160°C | ||
Product Type Digital Thermometer | ||
Model Number 1551A | ||
Thermometer Type Handheld | ||
Probe Type RTD | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Data Storage Yes | ||
Power Source Battery | ||
Resolutions Supported 0.001°C | ||
Battery Life 300h | ||
Length 114mm | ||
Height 25mm | ||
Width 57mm | ||
Standards/Approvals EN 61326:2006 | ||
Hazardous Area Certification ATEX | ||
Weight 196g | ||
Minimum/Maximum Recordings Yes | ||
Application Industrial | ||
Temperature Scale °C, Fahrenheit, F | ||
Intrinsically Safe Yes | ||
Battery Type 3 x AAA Alkaline | ||
Non conforme
- Pays d'origine :
- CN
Fluke Digital Thermometer, ±0.05°C Accuracy, 160°C Maximum Temperature Measurement - 1551A-9-DL
Features & Benefits
• Measures up to 160°C to cover common process ranges
• Intrinsically safe design allows use in classified hazardous areas
• Stores measurement data to assist traceable logging
• Wired RTD probe input enables robust sensor connectivity
**Applications**
• Ideal for temperature transmitter calibration in process control
• Used for custody transfer and PET calibration checks
• Can be used for on-site verification of industrial RTDs
• Used with loop and pressure calibrators during maintenance
What power source does it use and how long will it run between battery changes?
Which measurement scales and probe type are supported?
Is the instrument suitable for use in potentially explosive atmospheres?
How is measurement history handled for audits or verification?
Note
Supplied with
Liens connexes
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS