TRACOPOWER TVN 3 DC/DC Converter, 15V dc/ 100 mA, 13.2V dc Input, 4.5V Input 3 W, Through Hole, 90 °C Max Temp -40 °C

Offre groupée disponible
Consulter les options de prix de gros

Sous-total (1 tube de 10 unités)*

390,47 €

(TVA exclue)

472,47 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Temporairement en rupture de stock
  • Expédition à partir du 22 mars 2027
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails

Tube(s)
le tube
Prix par unité*
1 - 4390,47 €39,047 €
5 - 9378,74 €37,874 €
10 - 24367,02 €36,702 €
25 - 49351,41 €35,141 €
50 +335,79 €33,579 €

*Prix donné à titre indicatif

N° de stock RS:
146-5920
Référence fabricant:
TVN 3-0923
Fabricant:
TRACOPOWER
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

TRACOPOWER

Product Type

DC/DC Converter

Output Voltage 1

15V dc

Minimum Input Voltage

4.5V

Maximum Input Voltage

13.2V dc

Output Current 1

100mA

Output Current 2

100mA

Mount Type

Through Hole

Output Voltage 2

-15V dc

Input Ratio

2:1

MTBF

5600000h

Number of Outputs

2

Number of Pins

12

Isolation Voltage

1.6kV dc

Maximum Output Power

3W

Package Type

SIP

Standards/Approvals

No

Length

21.8mm

Width

9.6mm

Series

TVN 3

Depth

11.2mm

Minimum Operating Temperature

-40°C

Efficiency

81%

Maximum Operating Temperature

90°C

Pays d'origine :
TW
The THM 15WI series is a range of medical 15 Watt DC/DC converters in 1.6” x 1.0” plastic package and with wide 2:1 input voltage range. They provide a reinforced isolation system for 5000 VACrms isolation and a very low leakage current of less than 2.5 μA. The units are approved to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP (Means Of Patient Protection) and come along with an ISO 14971 risk management file. Design and production conform to the quality management system ISO 13485.

I/O isolation 5000 VACrms rated for 250 VACrms working voltage

Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP

Risk management process according to ISO 14971 including risk management file

Extended operating temperature range –40°C to 85°C.

EMC compliance to IEC 60601-1-2 4th edition and EN55032 class A

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail

Les données personnelles que vous nous fournissez en vous inscrivant à cette liste de diffusion seront traitées conformément à notre politique de confidentialité.