ABB GJL131 Contactor, 380V, 415 V, 380 V, 415 V Coil, 3-Pole, 12 A, 5.5 kW 415V, 4 NO, 690V
- N° de stock RS:
- 721-287
- Référence fabricant:
- GJL1311009R8105
- Fabricant:
- ABB
Visuel non contractuel
Sous-total (1 unité)*
52,18 €
(TVA exclue)
63,14 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 52,18 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 721-287
- Référence fabricant:
- GJL1311009R8105
- Fabricant:
- ABB
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 380, 415, 380, 415V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 12A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Function | Mini Contactor | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Terminal Type | Solder Pin | |
| Operational Current Ie | 6A | |
| Control Circuit Voltage Uc | 415V | |
| Contactor Application | Control Unit | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 55°C | |
| Width | 48mm | |
| Depth | 47.7mm | |
| Length | 47.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Pole and Throw Configuration | 3 | |
| Sélectionner tout | ||
|---|---|---|
Marque ABB | ||
Product Type Contactor | ||
Coil Voltage 380, 415, 380, 415V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 12A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Function Mini Contactor | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Terminal Type Solder Pin | ||
Operational Current Ie 6A | ||
Control Circuit Voltage Uc 415V | ||
Contactor Application Control Unit | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 55°C | ||
Width 48mm | ||
Depth 47.7mm | ||
Length 47.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Pole and Throw Configuration 3 | ||
- Pays d'origine :
- DE
ABB GJL131 Series Contactor, 12A Contact Current, 5.5kW Power Rating - GJL1311009R8105
This contactor is a Compact switching device designed to control three-phase loads in commercial electrical installations. It operates as a small-format contactor suitable for DIN-rail mounting and is intended for motor control and general switching tasks where space-saving and clear control circuit voltages are required.
Features and Benefits:
• Three-pole switching gives straightforward three-phase control
• Rated operational current 12 A supports moderate load demands
• Power handling 5.5 kW enables small motor applications
• Control circuit voltage 380 V/415V suits standard supply systems
• Rated contact voltage 690V provides high-voltage compatibility
• Solder pin terminals permit secure PCB or connector connections
• Rated operational current 12 A supports moderate load demands
• Power handling 5.5 kW enables small motor applications
• Control circuit voltage 380 V/415V suits standard supply systems
• Rated contact voltage 690V provides high-voltage compatibility
• Solder pin terminals permit secure PCB or connector connections
Applications
• Suitable for Compact motor starters in commercial buildings
• Ideal for automation panels requiring DIN-rail components
• Used for switching three-phase heaters and resistive loads
• Can be used for small pump and fan motor control circuits
• Used with control systems needing a single auxiliary contact
• Ideal for automation panels requiring DIN-rail components
• Used for switching three-phase heaters and resistive loads
• Can be used for small pump and fan motor control circuits
• Used with control systems needing a single auxiliary contact
What ambient temperature range can it operate within?
It functions correctly between -25°C and 55°C, covering typical indoor commercial environments.
How many auxiliary contacts are provided and in what configuration?
It includes a single auxiliary contact arranged as one normally open contact for signalling or interlock use.
What mounting method is required for installation?
It is designed for DIN-rail mounting to integrate into standard electrical distribution assemblies.
How many main poles does it contain and what is the pole configuration?
It contains three main poles in a 3P arrangement for three-phase switching.
Which standards does it comply with for use in industrial setups?
It meets relevant IEC/EN and UL standards for low-voltage switching as listed in the technical data.
Liens connexes
- ABB GJL131 Contactor 415 V 415 V Coil 12 A 4 NO, 690V
- ABB GJL131 Contactor 415 V 415 V Coil 20 A 4 NO, 690V
- ABB GJL131 Contactor 415 V Coil 20 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V 415 V Coil 20 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V 415 V Coil 12 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V Coil 20 A 3 NO/1 NC, 690V
- ABB GJL121 Contactor 415 V Coil 20 A 415 V 690V dc
- ABB GJL121 Contactor 415 V ac Coil 20 A 3 NO/1 NC, 690V