    Thermal breakers protect circuits from excess current in a similar way to a fuse, however, they often feature a switch allowing them to be reset if tripped. Common types of thermal breakers include thermal magnetic circuit breakers and thermal automotive circuit breakers.

    Types of Thermal Breakers

    Thermal magnetic circuit breakers are devices that provide protection against overcurrent in circuits. Circuit breakers use an automatically operated electrical switch to disrupt the flow of current when an overload or short circuit is detected. Thermal magnetic circuit breakers do this using an electromagnet and bimetallic strips.

    Circuit breakers provide more sophisticated protection against overcurrent than a simple fuse. Fuses simply burn out and have to be replaced, whereas circuit breakers just need to be reset.

    Thermal automotive circuit breakers are devices used to break the flow of current in automotive circuits, in order to protect them against a fault such as overcurrent or short circuit.

    The thermal aspect of this type of circuit breaker allows for smaller overcurrents over a longer period of time, but will quickly trip the circuit for larger overcurrents. This is useful in the case of motors, as there will be a small overcurrent each time the engine is switched on for a short length of time, which should not trip the circuit.

    What are thermal magnetic circuit breakers used for?

    Thermal magnetic circuit breakers are most often used in distribution boards. They make up part of the subsidiary circuits in the broader electrical supply system, protecting against overcurrent.

    What are thermal automotive circuit breakers used for?

    Thermal automotive circuit breakers are used to protect electrical networks in most types of vehicles, including cars, vans, buses, and boats.

    1404 Produits présentés pour Thermal Breakers

    ETA
    4A
    1
    -
    250V
    11.5mm
    3600
    -
    Thermal-Magnetic
    Button
    -
    250V
    -
    -
    Panel Mount
    ETA
    16A
    5
    -
    50 V DC, 240 V AC
    28mm
    3120-N
    -
    -
    -
    -
    -
    -
    -
    -
    Schurter
    2.5A
    1
    -
    240V ac
    -
    T11
    -
    Thermal
    -
    -
    -
    -
    -
    -
    Schneider Electric
    50A
    3
    TeSys
    690V
    55mm
    GV3
    Motors
    Thermal-Magnetic
    -
    -
    690V
    Yes
    Green Premium
    DIN Rail Mount
    TE Connectivity
    5A
    1
    -
    50 V dc, 250V ac
    17.52mm
    W23
    -
    Thermal
    -
    -
    -
    -
    -
    -
    Phoenix Contact
    10A
    1
    Thermomagnetic Device Circuit Breaker
    50V dc
    12.3mm
    CB
    -
    -
    -
    -
    -
    -
    -
    -
    ETA
    6A
    1
    -
    240V
    11mm
    106
    -
    Thermal
    Button
    -
    240V
    -
    -
    Panel Mount
    Schneider Electric
    40A
    3
    TeSys Deca
    690V
    55mm
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schurter
    3A
    2
    TA36 Rocker
    60 V dc, 277 V ac
    26
    TA36
    -
    -
    -
    -
    -
    -
    -
    -
    TE Connectivity
    2A
    1
    -
    50 V dc, 250V ac
    17.52mm
    W23
    -
    Thermal
    -
    -
    -
    -
    -
    -
    Phoenix Contact
    500mA
    2
    -
    80V dc
    24.6mm
    CB TM2
    -
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    500mA
    1
    -
    277 V ac, 415V ac
    15mm
    GB2
    -
    -
    -
    -
    -
    -
    -
    DIN Rail Mount
    Schneider Electric
    50A
    3
    TeSys
    690V ac
    116mm
    GV4LE
    -
    Magnetic
    -
    -
    690V
    Yes
    Green Premium
    -
    Schneider Electric
    80A
    3
    TeSys
    690V ac
    116mm
    GV4PE
    -
    Thermal-Magnetic
    -
    -
    690V
    Yes
    Green Premium
    -
    ETA
    12A
    2
    -
    50 V DC, 240 V AC
    36.2mm
    3120-N
    -
    -
    -
    -
    -
    -
    -
    -
    Schurter
    16A
    2
    TA36 Rocker
    60 V dc, 277 V ac
    26mm
    TA36
    -
    -
    -
    -
    -
    -
    -
    -
    Phoenix Contact
    3A
    1
    -
    65 V dc, 250V ac
    12.5mm
    TMC M1
    -
    -
    -
    -
    -
    -
    -
    DIN Rail Mount
    Schneider Electric
    3A
    1
    -
    277 V ac, 415V ac
    15mm
    GB2
    -
    -
    -
    -
    -
    -
    -
    DIN Rail Mount
    Phoenix Contact
    16A
    -
    -
    250V
    38mm
    TMCP
    -
    Thermal-Magnetic
    -
    -
    250V
    -
    -
    -
    Altech
    3A
    2
    -
    277V
    35mm
    V-EA
    AC Discharge Lamps (Ballast), AC General Use, AC Incandescent Lamps (Tungsten), AC Motor Starting, AC Resistance, Across the Line, High Efficiency Motors, UL508 Application, Which have Exceedingly High Inrush Current
    Thermal-Magnetic
    Handle
    Type E
    480Y/277V
    -
    -
    DIN Rail Mount
    Résultats par page