Siemens 6XV1830 Series Bus Cable 20 m Black Sheath Polyvinyl Chloride

Sous-total (1 bobine de 20 mètres)*

100,29 €

(TVA exclue)

121,35 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stock limité
  • Plus 2 unité(s) expédiée(s) à partir du 09 novembre 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Bobine(s)
la bobine
le mètre*
1 +100,29 €5,015 €

*Prix donné à titre indicatif

N° de stock RS:
203-3315
Référence fabricant:
6XV1830-3FH10
Fabricant:
Siemens
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Siemens

Product Type

Bus Cable

Cable Length

20m

Jacket Colour

Black

Outside Diameter

8mm

Jacket Material

Polyvinyl Chloride

Minimum Operating Temperature

-40°C

Conductor Type

Stranded

Maximum Operating Temperature

+60°C

Standards/Approvals

CE, RoHS Compliant

Series

6XV1830

Fire Behaviour

Inflammable

Voltage

80V

Pays d'origine :
DE

Siemens 6XV1830 Series Bus Cable, 20m Cable Length, 8mm Outside Diameter - 6XV1830-3FH10


This bus cable is a two-core underground PROFIBUS FC communication cable designed for buried installation and sold by the metre. It combines a stranded conductor and a screened construction with an extra protective outer cover to withstand mechanical stress when laid in the ground. The cable operates at low voltage and is suitable for industrial automation wiring where a robust, temperature-resistant link is required.

Features and Benefits:


• 80V RMS rated voltage providing safe low-voltage operation
• -40°C to +60°C ambient range enabling wide temperature resilience
• 150Ω characteristic impedance ensuring consistent signal integrity
• Overlapped foil and braided screen reducing external interference
• PE/PVC outer sheath protecting against mechanical damage

Applications


• Suitable for buried PROFIBUS FC installations in control networks
• Used with automation field devices requiring screened data links
• Ideal for factory floor cabling exposed to oil and water
• Used for outdoor runs where UV resistance is required

What conductor construction does it use?


It uses stranded conductors with PE insulation for flexibility and signal performance.

How does the cable manage electromagnetic interference?


It combines overlapped aluminium-clad foil with a tin-plated copper braid to provide a screened path for noise.

What mechanical protections are provided for ground installation?


An additional outer cover of PE provides abrasion resistance

the outer sheath must be removed for connector attachment.

How is signal attenuation specified across frequencies?


Attenuation is specified as maximum 0.0025 dB/m at 9.6kHz and 0.042 dB/m at 16 MHz.

What approvals and environmental conformities are declared?


It carries CE marking, RoHS conformity and EAC approval and meets fire classification EN13501-6 Fca.