RS PRO Type T Thermocouple 2 m Length, 0.3 mm Diameter → 350 °C Max

Offre groupée disponible

Sous-total (1 unité)*

8,91 €

(TVA exclue)

10,78 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • Plus 127 unité(s) expédiée(s) à partir du 27 avril 2026
  • Plus 285 unité(s) expédiée(s) à partir du 27 avril 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails

Unité
Prix par unité
1 - 48,91 €
5 - 98,46 €
10 +8,17 €

*Prix donné à titre indicatif

N° de stock RS:
621-2209
Numéro d'article Distrelec:
304-19-530
Fabricant:
RS PRO
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

RS PRO

Thermocouple Type

T

Product Type

Thermocouple

Probe Diameter

0.3mm

Probe Length

2m

Maximum Temperature Sensed

350°C

Cable Length

2m

Standards/Approvals

RoHS Compliant

Response Time

0.7s

Pays d'origine :
FR

Features & Benefits


Type T welded tip

2000 mm Length

‐40°C to 120°C ±1.5°C

2 cable 0.07 mm² CSA

RS Pro Glassfibre IEC Exposed Welded Tip Thermocouples


From RS Pro a range of Type J, K, T & N wire type thermocouple temperature sensors conforming to IEC 60584 standards. These thermocouples have a welded exposed hot junction for a fast response time and cable conductors surrounded by a glassfibre insulation.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


An exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Properties of Glassfibre Insulation


Glassfibre wire insulation is flexible with a good temperature range but does not prevent the ingress of fluids

Key Features and Benefits


• Welded, exposed junction for fast response times

• Glassfibre insulated cable for good flexibility and temperature range

• Conforms to IEC 60584 standards

Applications


These grounded junction Type J, K, T & N wire thermocouples are ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Liens connexes