RS PRO Type K Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +250°C
- N° de stock RS:
- 239-4534
- Fabricant:
- RS PRO
Sous-total (1 unité)*
14,04 €
(TVA exclue)
16,99 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
Stock limité
- 14 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 14,04 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 239-4534
- Fabricant:
- RS PRO
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | RS PRO | |
| Thermocouple Type | K | |
| Probe Diameter | 1/0.3mm | |
| Probe Length | 1m | |
| Maximum Temperature Sensed | +250°C | |
| Probe Material | PFA | |
| Termination Type | Miniature Plug | |
| Series | XQ | |
| Cable Length | 1m | |
| Standards Met | JIS | |
| Sélectionner tout | ||
|---|---|---|
Marque RS PRO | ||
Thermocouple Type K | ||
Probe Diameter 1/0.3mm | ||
Probe Length 1m | ||
Maximum Temperature Sensed +250°C | ||
Probe Material PFA | ||
Termination Type Miniature Plug | ||
Series XQ | ||
Cable Length 1m | ||
Standards Met JIS | ||
- Pays d'origine :
- GB
RS PRO Type K Exposed Junction Thermocouple and Miniature Plug
From RS PRO a range of Type K wire temperature sensing thermocouples that are RoHS compliant. These Type K fine wire temperature sensors have durable PFA insulated twin-twisted 1/0.2 mm, 1/ 0.3 mm or 7/0.2 mm lead. The lead is terminated with a rewireable miniature flat pin plug for a quick and easy connection. These thermocouples have an exposed welded junction which enables them to operate with a fast response time.
How does a Thermocouple Work?
A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect.
What is a Welded Exposed Junction?
An exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures.
Features and Benefits
Applications
These Type K wire thermocouple temperature sensors are ideal for test and development applications including test and measurement, temperature mapping and OEM applications.
Liens connexes
- RS PRO Type K Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +250°C
- RS PRO Type J Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +250°C
- RS PRO Type T Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +250°C
- RS PRO Type K Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +220°C
- RS PRO Type K Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +260°C
- RS PRO Type K Exposed Junction Thermocouple 1m Length, 1/0.3mm Diameter → +350°C
- RS PRO Type K Exposed Junction Thermocouple 1m Length -60°C → +350°C
- RS PRO Type K Exposed Junction Thermocouple 2m Length, 1/0.3mm Diameter → +250°C