RS PRO Type K Exposed Junction Thermocouple 3 m Length, → 250 °C Max

Offre groupée disponible

Sous-total (1 unité)*

20,19 €

(TVA exclue)

24,43 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • Plus 12 unité(s) expédiée(s) à partir du 27 avril 2026
  • Plus 204 unité(s) expédiée(s) à partir du 27 avril 2026
  • Plus 43 unité(s) expédiée(s) à partir du 29 avril 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails

Unité
Prix par unité
1 - 420,19 €
5 - 919,24 €
10 +18,15 €

*Prix donné à titre indicatif

N° de stock RS:
131-4754
Numéro d'article Distrelec:
304-14-009
Fabricant:
RS PRO
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

RS PRO

Thermocouple Type

K

Product Type

Exposed Junction Thermocouple

Probe Length

3m

Maximum Temperature Sensed

250°C

Probe Material

PFA

Cable Length

3m

Standards/Approvals

IEC, RoHS Compliant

Pays d'origine :
GB

RS Pro IEC Type K Exposed Junction Fast Response Thermocouple with Moulded Miniature Plug


From RS Pro a range of type K thermocouple temperature sensors conforming to IEC-584-3 standards with a Class 1 tolerance. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The twin-twisted leads have a durable Teflon PFA insulation and are terminated one end with a moulded miniature flat pin plug which is colour coded green in accordance with IEC. The moulded plug has a a robust construction, provides a waterproof termination and enables a quick and easy connection.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


A welded exposed junction is where the thermocouple wires are welded together but are not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Features and Benefits


• Welded, exposed junction for fast response times

• IEC-584-3 Class 1 tolerance for optimum accuracy

• Durable Teflon PFA lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility

• Miniature moulded plug with robust design for quick connection and waterproof termination

• Temperature range of -75 to +250°C

Applications


Exposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications include test and development, test and measurement, temperature mapping and OEM applications.

Note

Small Pack Size:131-4754
Large Pack Size:262-3202