RS PRO Type K Exposed Junction Thermocouple 2 m Length, → 260 °C Max

Offre groupée disponible
Consulter les options de prix de gros

Sous-total (1 unité)*

15,71 €

(TVA exclue)

19,01 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • Plus 1 032 unité(s) expédiée(s) à partir du 08 juin 2026
  • Plus 6 645 unité(s) expédiée(s) à partir du 08 juin 2026
  • Plus 670 unité(s) expédiée(s) à partir du 16 juin 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails

Unité
Prix par unité
1 - 415,71 €
5 - 914,94 €
10 +14,10 €

*Prix donné à titre indicatif

N° de stock RS:
110-4482
Numéro d'article Distrelec:
303-90-641
Fabricant:
RS PRO
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

RS PRO

Product Type

Exposed Junction Thermocouple

Thermocouple Type

K

Probe Length

2m

Maximum Temperature Sensed

260°C

Probe Material

PTFE

Cable Length

2m

Standards/Approvals

IEC, RoHS Compliant

Pays d'origine :
GB

RS Pro IEC Type J, K & Type T Fine Wire Exposed Junction Thermocouple and Miniature Plug


From RS Pro a range of Type J, K and Type T fine wire temperature sensing thermocouples that conform to IEC-584-3 standards with a Class 1 tolerance for optimum performance. These Type K and Type T fine wire temperature sensors have a durable Teflon PTFE insulated class 1 twin-twisted 1/0.2 mm lead. The lead is terminated with a rewireable miniature flat pin plug for a quick and easy connection. These thermocouples have an exposed welded junction which enables them to operate with a fast response time.

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


An exposed junction is where the thermocouple wires are welded together but not surrounded by the outer sheath. The ends of the wire are directly inserted into the process. This means the thermocouple has a high sensitivity and response time. Welded exposed junctions are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures

Features and Benefits


• IEC-584-3 class 1 tolerance for optimum accuracy

• Miniature plug for quick and easy connection

• Exposed welded junction for fast response

• Durable Teflon PTFE insulation for resistance to oils, acids and fluids and good mechanical strength and flexibility

• Temperature range from -75 to +250°C

Applications


These Type J, K and Type T fine wire thermocouple temperature sensors are ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Note

Small Pack Size:110-4482
Large Pack Size:262-3191

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail

Les données personnelles que vous nous fournissez en vous inscrivant à cette liste de diffusion seront traitées conformément à notre politique de confidentialité.