RS PRO Type T Exposed Junction Thermocouple 1 m Length, 1 mm Diameter, -50 °C → 250 °C Max

Offre groupée disponible

Sous-total (1 paquet de 5 unités)*

33,46 €

(TVA exclue)

40,485 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • Plus 5 unité(s) expédiée(s) à partir du 27 avril 2026
  • Plus 40 unité(s) expédiée(s) à partir du 27 avril 2026
  • Plus 190 unité(s) expédiée(s) à partir du 25 mai 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails

Unité
Prix par unité
le paquet*
5 - 206,692 €33,46 €
25 - 456,356 €31,78 €
50 +6,024 €30,12 €

*Prix donné à titre indicatif

N° de stock RS:
158-907
Fabricant:
RS PRO
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

RS PRO

Thermocouple Type

T

Product Type

Exposed Junction Thermocouple

Probe Diameter

1mm

Probe Length

1m

Probe Material

Polytetrafluoroethylene

Maximum Temperature Sensed

250°C

Terminal Type

Cable

Cable Length

1m

Standards/Approvals

BS

Minimum Temperature Sensed

-50°C

Pays d'origine :
GB

RS Pro BS1843 Type K & Type T Exposed Junction Wire Thermocouple


From RS Pro type K and Type T thermocouple temperature sensors colour coded to the former British Standard – BS1843-1952 with a Class 1 tolerance in accordance with IEC 584-2 (formerly BS4937:1983) standards for optimum accuracy. These thermocouple temperature sensors feature a welded tip exposed junction for a fast response time. The leads have a durable PTFE insulation for resistance to oils, acids and other fluids

How does a Thermocouple Work?


A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

What is a Welded Exposed Junction?


In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.

Features and Benefits


• Welded, exposed junction for fast response times

• IEC-584-2 Class 1 tolerance for optimum accuracy

• Durable PTFE lead insulation for resistance to oils, acid, fluids and good mechanical strength and flexibility

Applications


Exposed junction thermocouples are more prone to corrosion and are recommended for measuring flowing or static non-corrosive gas temperatures. Applications for these Type K and Type T thermocouples include test and development, test and measurement, temperature mapping and OEM applications.

Old Colour Code, BS1843


Thermocouples, bayonet adaptors, compensating and extension cables and connectors.,These BS1843 products are being phased out, having been replaced with a new colour code standard BS4937 Part 30 1993 (IEC 584-3 1989 modified for international use). System Calibration is available on selected probes and includes the full charge of the instrument and probe.

Liens connexes