ETA Thermal Circuit Breaker - 3120 2 Pole 250V Voltage Rating Snap In, 16A Current Rating
- N° de stock RS:
- 712-7648
- Référence fabricant:
- 3120-F551-H7T1-W14DR4-16A
- Fabricant:
- ETA
Indisponible
RS n'aura plus ce produit en stock.
Produit de remplacement
Ce produit n'est pas disponible actuellement. Voici notre produit de remplacement:
la pièce
31,68 €
(TVA exclue)
38,33 €
(TVA incluse)
- N° de stock RS:
- 712-7648
- Référence fabricant:
- 3120-F551-H7T1-W14DR4-16A
- Fabricant:
- ETA
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | ETA | |
| Current Rating | 16A | |
| Number of Poles | 2 | |
| Voltage Rating | 250V | |
| Width | 25mm | |
| Series | 3120 | |
| Tripping Mechanism | Thermal | |
| Reset Actuator Type | Rocker | |
| Rated AC Voltage | 250V | |
| Mounting Style | Snap In | |
| Rated DC Voltage | 50V | |
| Circuit Breaker Type | Thermal Circuit Breaker | |
| Terminal Contact Type | Blade | |
| Overall Depth | 35mm | |
| Overall Dimensions | 41 x 25 x 35mm | |
| Overall Length | 41mm | |
| Sélectionner tout | ||
|---|---|---|
Marque ETA | ||
Current Rating 16A | ||
Number of Poles 2 | ||
Voltage Rating 250V | ||
Width 25mm | ||
Series 3120 | ||
Tripping Mechanism Thermal | ||
Reset Actuator Type Rocker | ||
Rated AC Voltage 250V | ||
Mounting Style Snap In | ||
Rated DC Voltage 50V | ||
Circuit Breaker Type Thermal Circuit Breaker | ||
Terminal Contact Type Blade | ||
Overall Depth 35mm | ||
Overall Dimensions 41 x 25 x 35mm | ||
Overall Length 41mm | ||
- Pays d'origine :
- TN
CBE, 1 Pole Sensing, 2 Pole Switching and Illuminating, 3120 Series
IEC Classification S/TO (with module, S/TM), Illuminated switch and circuit breaker combined units which offer both mechanical and visual indication of contact position and power status. Available in red or green illumination (suitable for medical applications).
H7T1 Variant units can also be converted to thermal magnetic type, for faster response to gross overloads, or to no volt release products to protect sensitive equipment.
H7T1 Variant units can also be converted to thermal magnetic type, for faster response to gross overloads, or to no volt release products to protect sensitive equipment.
Depth behind panel: 43mm
Basic tripping time at 2xIN 20-30 seconds
Circuit protection designed for equipment, sub-systems and components
Basic tripping time at 2xIN 20-30 seconds
Circuit protection designed for equipment, sub-systems and components
Approvals
UL, CSA, VDE, BV
Approvals
UL. CSA, VDE
Thermal Magnetic Convertible
All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).
Liens connexes
- ETA Thermal Circuit Breaker - 3120 2 Pole 250V Voltage Rating Snap In, 3A Current Rating
- ETA Thermal Circuit Breaker / Switch - 2 Pole Snap In, 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 16A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 1A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 2.5A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 2 Pole 50 V DC 12A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 20A Current Rating
- ETA Thermal Circuit Breaker - 3120-N 5 Pole 50 V DC 10A Current Rating