Jumo Jumo TYA-200 Surface Mount Power Controller Current 400V ac Power Controller

Sous-total (1 unité)*

1 842,84 €

(TVA exclue)

2 229,84 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité
Prix par unité
1 +1 842,84 €

*Prix donné à titre indicatif

N° de stock RS:
793-4060
Numéro d'article Distrelec:
304-22-859
Référence fabricant:
709062/8-01-050-001-400-00/252
Fabricant:
Jumo
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Jumo

Product Type

Power Controller

Output Type

Current

Maximum Current

250A

Maximum Operating Temperature

45°C

Minimum Operating Temperature

0°C

Terminal Type

Screw

Control Type

Power Controller

Maximum Supply Voltage

400V ac

Diagnostics

Yes

Firing Mode

Burst Fire, Phase Angle Operation

Digital Comms

PROFIBUS-DP, RS422 (Modbus RTU), RS485

Display Type

LCD

Maximum Voltage

500V

Length

160mm

Width

200 mm

Standards/Approvals

UL, cULus

IP Rating

IP20

Mount Type

Surface Mount

Input Type

Voltage

Series

Jumo TYA-200

Panel Depth

195mm

Pays d'origine :
DE

TYA-202 3-Phase Power Controller


The micro-processor controlled three-phase power controller Jumo TYA 202 displays all parameters in a backlighted LCD display and is operated using the 4 keys on the front.

SCR power controllers are employed where larger resistive and ohmic-inductive loads have to be switched, e.g. in industrial kiln construction and in plastics processing. The SCR power controller comprises two SCRs connected in anti-parallel, the insulated cooling body and the control electronics.

The operating modes are burst-firing mode, SSR logical operation, fast logical operation, alpha start and soft start.

Available subordinate controls are U, U2, I, I2 and P control.

Use of a subordinate control ensures that fluctuations in the supply voltage do not affect the control loop during the control process.

Three-phase SCR power controller

Simple configuration of the device through plain text display

Setup program for configuration via USB interface

Transmission of the setup data is possible even without voltage supply to the device (USB port supplies power)

Network load optimization through dual energy management

Burst-firing mode

Soft start function with pulse groups

Resistance monitoring and limitation for MoSi2 heating elements

Teach-in function for the detection of partial load failure

Integrated diagnostic systems (e.g. rotating field detection)

Liens connexes