Jumo 601540 Controller 230V Controller

Sous-total (1 unité)*

341,91 €

(TVA exclue)

413,71 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 23 avril 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +341,91 €

*Prix donné à titre indicatif

N° de stock RS:
278-743
Référence fabricant:
601540/056-048-13-01-150-15/000
Fabricant:
Jumo
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Jumo

Product Type

Controller

Maximum Current

20mA

Minimum Operating Temperature

50°C

Maximum Operating Temperature

80°C

Control Type

Controller

Maximum Supply Voltage

230V

Maximum Voltage

400V

Standards/Approvals

DIN 16257, RoHS

Length

150mm

IP Rating

IP54

Series

601540

Pays d'origine :
DE
The Jumo Exhaust gas temperature monitor features a robust die cast aluminium case as well as the 150 mm long, stable steel protection tube guarantee operation even in rough conditions. Due to the used rod expansion principle the exhaust gas temperature monitor can be used up to a maximum sensor temperature of 700 °C. The maximum permissible ambient temperature at the case (protection class IP54) is between -50 °C and +80 °C. The electrical connection is made directly with screw terminals on the installed microswitch, which can directly switch a maximum permissible switching capacity of AC 230V/10A. At the set limit value, the system switches from one circuit to the other. The thermostat has a switching differential (hysteresis) of 10 to 18 K and automatically switches back to the original state after the temperature falls below the switch off temperature by this value. Furthermore it is used to block ventilation systems causing vacuum in connection with tile stoves and fireplaces.

Integrated micro switch

Contact reliability

Fast reaction time of 45 seconds in flue gas and is authorized according to DIN EN 14597

Can be installed directly in the flue gas duct by the screw connection with G 1/2 inch thread

No additional auxiliary energy is necessary for temperature measurement

Monitor the flue gas temperature of solid fuel boilers during bivalent operation with oil heating boilers

Liens connexes