Eaton 90A Tag Fuse 25 mm 1kV

Sous-total (1 unité)*

140,07 €

(TVA exclue)

169,48 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 04 janvier 2027
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +140,07 €

*Prix donné à titre indicatif

N° de stock RS:
282-6210
Référence fabricant:
FWE-90A
Fabricant:
Eaton
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Eaton

Product Type

Tag Fuse

Current Rating

90A

Fuse Size

25 mm

Voltage

1kV

Standards/Approvals

UL 248-13, IEC 60269-4, CE

Application Category

EV Charging Stations

High Rupture Capacity

Yes

Length

110mm

Width

25.4mm

Height

110mm

Series

FWE

Non conforme

Pays d'origine :
CN

Eaton Tag Fuse, 90A Current Rating, 1 kV Voltage Rating - FWE-90A


This high-speed 90A tag fuse from Eaton with a 25mm fuse size and CE and IEC 60269-4 fuse standard compliance is designed for the protection of high-power DC charging station applications. With a voltage rating of 1kV, it offers a wide range of solutions for DC conditioning circuits and high voltage DC/DC converters, making it ideal for up to 400kW+ rated chargers.

Features & Benefits


• Wide range of solutions for DC conditioning circuits and high voltage DC/DC converters

• Supports charger output ratings up to 1000VDC as per CCS & CHAdeMO Protocols

• Compact design with low minimum breaking current for easy coordination within DC applications

• Demonstrated performance in extreme temperature cycling conditions for maximum protection

• Reduces dimensioning requirements of DC contactors, optimising space and decreasing overall system cost

Applications


• DC Charging stations for private and public places

• Specialist vehicle onboard • General DC power conversion equipment and battery systems

Can it support a wide range of charger output ratings?


Yes, it supports charger output ratings up to 1000VDC as per CCS & CHAdeMO Protocols.

Will it reduce dimensioning requirements of DC contactors?


Yes, it reduces dimensioning requirements to optimise space and decrease system cost.

Is it suitable for extreme temperature cycling conditions?


Yes, it is demonstrated to perform well in extreme temperature cycling conditions for maximum protection.