Phoenix Contact MACX MCR Series Signal Conditioner, Voltage Input, Current, Voltage Output, 24V dc Supply

Sous-total (1 unité)*

371,20 €

(TVA exclue)

449,15 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • 2 unité(s) prête(s) à être expédiée(s)
  • Plus 4 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +371,20 €

*Prix donné à titre indicatif

N° de stock RS:
171-7044
Numéro d'article Distrelec:
303-48-083
Référence fabricant:
2906244
Fabricant:
Phoenix Contact
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Phoenix Contact

Module Type

Voltage Transducer

Input Signal Type

Voltage

Output Signal Type

Current, Voltage

Input Range

0 → 550V ac

Output Range

-10 → 10 V, -20 mA → 20mA

Supply Voltage

24V dc

Mounting Type

DIN Rail Mount

Operating Temperature Range

-25 → +60°C

Series

MACX MCR

Maximum Operating Temperature

+60°C

Standards Met

CE, cUL, CULus, EAC, EN 61000-6-2, EN 61000-6-4, IEC 61010-1, IEC 61010-2-030, UL

Minimum Operating Temperature

-25°C

Pays d'origine :
DE

Phoenix Contact Voltage Measuring Transducer, 24V DC, 22mA - MACX MCR-VAC-PT - 2906244


This transducer from Phoenix Contact is a sensor that sends data to a monitoring device such as a PLC (programmable logic controller). It sends the data in the form of volts, providing a reading in DC (direct current) voltage of the same relative amount as the AC (alternate current) voltage.
The unit has an adjustable voltage range, so you can set it to suit your specifications. It has three-way isolation, which can control output signals at two separate points for bi-directional use. Push-in connection technology makes it simple to install.
The voltage transmission of this transducer means it's ideal for use with small devices and components that are less susceptible to electromagnetic interference (EMI). It converts currents in under 180ms (milliseconds) for a rapid response.

Features & Benefits


• Low-level power consumption of under 45mA for greater energy efficiency
• Suitable for DIN rail mounting for ease of installation
• Compact dimensions of 99 (height) x 22.5 (width) x 114.5mm (depth) for installation in areas where space is limited
• Wide operating temperature range of -25°C to +60°C for use in a variety of environments

Adjustable voltage ranges
Bidirectional output signals
3-way isolation
ZERO/SPAN adjustment ±20%
Tool-free parameterization of measured values
Teach-in configuration of the measured value range

Liens connexes