SICK FLEXIL Series Input/Output Module, 2 Inputs, 5 Outputs, 24 V dc
- N° de stock RS:
- 213-3769
- Référence fabricant:
- FLA-PWRI00001
- Fabricant:
- SICK
Sous-total (1 unité)*
97,47 €
(TVA exclue)
117,94 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
Temporairement en rupture de stock
- 1 unité(s) expédiée(s) à partir du 04 mars 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 97,47 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 213-3769
- Référence fabricant:
- FLA-PWRI00001
- Fabricant:
- SICK
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | SICK | |
| Series | FLEXIL | |
| Product Type | Input/Output Module | |
| Sub Type | Module for Energy Supply | |
| For Use With | Flexi Soft System | |
| Supply Voltage | 24 V dc | |
| Number of Inputs | 2 | |
| Number of Outputs | 5 | |
| Terminal Type | M12 Connector | |
| Standards/Approvals | UL, CE | |
| Hazardous Area Certification | No | |
| Sélectionner tout | ||
|---|---|---|
Marque SICK | ||
Series FLEXIL | ||
Product Type Input/Output Module | ||
Sub Type Module for Energy Supply | ||
For Use With Flexi Soft System | ||
Supply Voltage 24 V dc | ||
Number of Inputs 2 | ||
Number of Outputs 5 | ||
Terminal Type M12 Connector | ||
Standards/Approvals UL, CE | ||
Hazardous Area Certification No | ||
- Pays d'origine :
- HU
Overview
At a glance
Your Benefit
Flexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.
Applications
Connecting both safety switches and safety sensors with OSSD outputs in series minimizes the amount of wiring and the number of inputs at the safety controller, thus reducing costs.
Simple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually
Quick and easy configuration saves time
Ability to be used over long distances increases application flexibility
Detailed diagnostic information – who switched and why? minimizes system downtime
Seamless system integration and communication with other SICK safety controllers
Detailed status information on Flexi Loop components, diagnostic accessories, and safety controller enable quick and easy field diagnosticsSeries connection of 32 sensors with up to 100 m per segment in compliance with performance level PL e
Compatible with sensors from all manufacturers
Detailed diagnostic information
Integrated standard inputs and outputs
Voltage supply for sensors is included
Liens connexes
- SICK FLEXIL Series Input/Output Module, 24 V dc
- SICK FLEXIL Series Input/Output Module, 16.8 → 30 V dc
- SICK Input/Output Module, 24 V
- SICK Input/Output Module 4 Outputs, 24 V
- SICK Input/Output Module 8 Outputs, 24 V
- SICK UE410 Series Input/Output Module 4 Outputs, 24 V dc
- SICK UE410 Series Input/Output Module 3 Outputs, 24 V dc
- SICK UE403 Series Input/Output Module, 24 V dc