SICK E100 Series Safety Enabling Switch, 2 NO/2 NC, IP65

Sous-total (1 unité)*

672,65 €

(TVA exclue)

813,91 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Stocké-e par le fabricant
  • Prêt à être expédié à partir du 21 janvier 2027
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +672,65 €

*Prix donné à titre indicatif

N° de stock RS:
285-1274
Référence fabricant:
E100-B2A22S25A
Fabricant:
SICK
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

SICK

Product Type

Safety Enabling Switch

Series

E100

Contact Configuration

2 NO/2 NC

IP Rating

IP65

Terminal Type

Cable

Housing Material

Plastic

Minimum Operating Temperature

-5°C

Switch Contact Current

2A

Contact Voltage

24V dc

Maximum Operating Temperature

50°C

Hazardous Area Certification

No

Standards/Approvals

China RoHS, cULus, EC-Type Examination, EN, EU DoC, TPC, UKCA

Depth

40.5mm

Width

63mm

Mechanical Life

100000Cycles

Length

132mm

Pays d'origine :
DE

SICK E100 Series Safety Enabling Switch, 24V DC Contact Voltage, IP65 - E100-B2A22S25A


This safety enabling switch provides a Compact control Interface for industrial safety installations, offering monitored contact outputs and straightforward cable termination for integration with safety logic units. It is housed in a plastic enclosure and operates across standard ambient conditions, designed for use where a Compact, ingress-protected interlock is required.

Features and Benefits:


• 2A rated contact current supports 24V DC control circuits
• 2 NO 2 NC contact configuration enables versatile safety logic
• IP65 ingress protection allows use in dusty or splashing environments
• Cable Terminal with 25m PUR cable simplifies installation
• Mechanical life of 100,000 cycles minimises maintenance needs

Applications


• Suitable for integration with safety controllers for machine stops
• Ideal for guard-door monitoring on production lines
• Used with access control systems requiring positive-action contacts
• Can be used for conveyor emergency-enable and reset functions

What fault behaviour should be expected if an internal failure occurs?


The device lacks internal fault detection, so a connected safety-related logic unit must monitor and determine the safe-state behaviour.

What are the conductor specifications within the supplied cable?


The straight cable contains conductors sized 8x0.5mm² and 8x0.14mm² with copper conductors and a PUR sheath.

How should short-circuit protection be specified for wiring?


Use fuses rated to 2A gG or 0.1A gG in the supply circuit, as appropriate to the wiring and load.

What are the permitted ambient temperatures for operation and storage?


The unit is specified for operation and storage between -5°C and +50°C.

What switching characteristics apply to low-current signals?


The switching principle is slow action, with switching currents down to 1mA at 24V DC for control signal detection.

Liens connexes