SICK FX3 Series Safety Controller, 96 Safety Inputs, 48 Safety Outputs, 24 V dc

Sous-total (1 unité)*

264,56 €

(TVA exclue)

320,12 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Pénurie d'approvisionnement
  • 14 restante(s), prêt à être expédié
  • Plus 7 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Notre stock actuel est limité et nos fournisseurs s'attendent à des pénuries.
Unité
Prix par unité
1 +264,56 €

*Prix donné à titre indicatif

N° de stock RS:
701-9196
Numéro d'article Distrelec:
304-01-241
Référence fabricant:
FX3-CPU000000
Fabricant:
SICK
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

SICK

Series

FX3

Product Type

Safety Controller

Number of Safety Inputs

96

Number of Safety Outputs

48

Mount Type

DIN Rail

Safety Category

4

Supply Voltage

24 V dc

Number of I/Os

3

Contact Current

4A

Contact Voltage

24V dc

Terminal Type

Spring Terminal

Standards/Approvals

CE, UL

Width

120.8 mm

Length

96.5mm

Depth

120.8mm

IP Rating

IP20

Flexi Soft Safety Controller, Main unit - FX3 CPU000000


Flexi Soft is a programmable and modularly expandable safety controller capable of being integrated into various networks. The main module FX3-CPU is the CPU of the entire system within which all input signals are monitored and processed via the safety logic stored in the memory plug. These signals are then used to switch outputs on the system through the FLEX BUS+ interface which connects all units to one another. The main unit has an RS-232 interface with which the Flexi Soft Designer can upload and change system settings. The RS-232 port can be used for permanent diagnosis (i.e. PLC or HMI) as well.,Functions: EDM, muting, operating mode switching. Logical functions: AND, NOT, OR, XNOR, XOR. Application specific logical functions: operating mode switch, muting, emergency stop, presses, two hand control.,For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a system. The gateways provide I/O Status and Error/Status Messaging. Additionally, non-safety related information can be sent to the Flexi Soft from the network. Each gateway can send and receive at least 50 Bytes of information.

System save in memory plug for a fast installation

Modular expandable (from 12 to 144 in/outputs maximum)

2.5 W power consumption

Intuitive free to download software: Flexi Soft Designer

Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849)

Note

The system memory plug (FX3-MPL) is sold separately

Liens connexes