Schneider Electric Acti9 iID Series Residual Current Circuit Breaker, 25 A, 4-Pole, 30 mA, Type AC, 1500 A 415 V ac
- N° de stock RS:
- 734-9129
- Référence fabricant:
- A9R11425
- Fabricant:
- Schneider Electric
Visuel non contractuel
Sous-total (1 unité)*
229,89 €
(TVA exclue)
278,17 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 229,89 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 734-9129
- Référence fabricant:
- A9R11425
- Fabricant:
- Schneider Electric
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 25 A | |
| Number of Poles | 4 | |
| Range | Acti9 | |
| Series | Acti9 iID | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type AC | |
| Mount Type | DIN Rail | |
| Standards/Approvals | EN/IEC 61008-1, REACH, RoHS | |
| Width | 36 mm | |
| Depth | 73.5mm | |
| Height | 91mm | |
| Breaking Capacity | 1500A | |
| Reset Actuator Type | Toggle Switch | |
| Rated AC Voltage | 415 V ac | |
| Earth Leakage Protection Type | AC | |
| Break Time | Instantaneous | |
| Sélectionner tout | ||
|---|---|---|
Marque Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 25 A | ||
Number of Poles 4 | ||
Range Acti9 | ||
Series Acti9 iID | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type AC | ||
Mount Type DIN Rail | ||
Standards/Approvals EN/IEC 61008-1, REACH, RoHS | ||
Width 36 mm | ||
Depth 73.5mm | ||
Height 91mm | ||
Breaking Capacity 1500A | ||
Reset Actuator Type Toggle Switch | ||
Rated AC Voltage 415 V ac | ||
Earth Leakage Protection Type AC | ||
Break Time Instantaneous | ||
- Pays d'origine :
- FR
RCCB Acti9 iID
The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.
iID residual current circuit breakers AC Type provide:
Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
iID residual current circuit breakers Asi Type provide:
Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.
Liens connexes
- Schneider Electric iID RCCB 2 Pole, 30mA
- Schneider Electric Acti9 iID RCCB 4 Pole 400V ac
- Schneider Electric Acti9 iID RCCB 4 Pole Type A, 380 → 415V ac
- Schneider Electric iID RCCB 4 Pole, 30mA
- Schneider Electric iID RCCB 4 Pole, 30mA
- Schneider Electric iID RCCB 2 Pole Type B-SI, 230V ac
- Schneider Electric iID RCCB 2 Pole Type B-EV, 230V ac
- Schneider Electric iID RCCB 4 Pole, 300mA