Siemens SENTRON Series Residual Current Circuit Breaker, 40 A, 4-Pole, 30 mA, Type A, 10 kA 400 V ac
- N° de stock RS:
- 211-9655
- Référence fabricant:
- 5SV3354-6
- Fabricant:
- Siemens
Sous-total (1 unité)*
372,69 €
(TVA exclue)
450,95 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 372,69 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 211-9655
- Référence fabricant:
- 5SV3354-6
- Fabricant:
- Siemens
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Series | SENTRON | |
| Range | SENTRON | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Standards/Approvals | VDE, CE, UKCA, EAC | |
| Height | 90mm | |
| Width | 72 mm | |
| Depth | 70mm | |
| Breaking Capacity | 10kA | |
| Rated AC Voltage | 400 V ac | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | Type A | |
| Tripping Mechanism | Electromagnetic | |
| Break Time | Instantaneous | |
| Sélectionner tout | ||
|---|---|---|
Marque Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Series SENTRON | ||
Range SENTRON | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Standards/Approvals VDE, CE, UKCA, EAC | ||
Height 90mm | ||
Width 72 mm | ||
Depth 70mm | ||
Breaking Capacity 10kA | ||
Rated AC Voltage 400 V ac | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type Type A | ||
Tripping Mechanism Electromagnetic | ||
Break Time Instantaneous | ||
- Pays d'origine :
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type A.Operating current is 40 A and trippening residual current 30 mA. Supply voltage is 500V. RCD is the residual current device for touch protection RCCBs, type A trip with both sinusoidal alternating currents (type AC) and pulsating DC residual currents. They are used mainly with single-phase consumers with electrical components in the supply unit, e.g. in residential and functional structures. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free