Eaton RCCB, 63A, 4 Pole, 30mA, Type B, 240/415V ac

Sous-total (1 unité)*

884,20 €

(TVA exclue)

1 069,88 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Temporairement en rupture de stock
  • Expédition à partir du 19 mars 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +884,20 €

*Prix donné à titre indicatif

N° de stock RS:
183-3549
Numéro d'article Distrelec:
304-21-859
Référence fabricant:
167894 FRCDM-63/4/003-G/B
Fabricant:
Eaton
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Eaton

Circuit Breaker Type

RCCB

Current Rating

63A

Number of Poles

4

Range

FRCdM

Trip Sensitivity

30mA

Tripping Characteristics

Type B

Voltage Rating

240/415V ac

Standards Met

IEC/EN 61008, IEC/EN 62423

Overall Length

70mm

Overall Dimensions

70 x 76 x 80mm

Rated AC Voltage

240V

Rated DC Voltage

220V

Break Time

Time Delay

Overall Width

76mm

Overall Depth

80mm

Terminal Contact Type

Screw

Mounting Style

DIN Rail Mount

Breaking Capacity at Maximum Voltage Rating

630 A

Pays d'origine :
CZ

Eaton RCD Switch, 240V AC / 220V DC Voltage Rating, Screw Terminals - FRCDM Series - 167894 FRCDM-63/4/003-G/B


Safeguard your home or workplace against electric hazards and the risk of fire with this RCD switch from Eaton. As it's an RCCB device, you can use it with a fuse or circuit breaker for assured residual current protection to BS EN 61008. It works by continuously monitoring connected circuits for earth leakage. The type-B tripping characteristic means it breaks the circuit when currents of 3 to 5 times the rated load are detected. Because it's a modular-style device, you can easily add on auxiliary contacts and restarting devices to enhance your electrical safety systems.

Features & Benefits


• Lifespan of more than 4,000 electrical and 20,000 mechanical operations for long-term use
• Short delay of 10ms allows transient currents to pass through to minimise nuisance tripping
• Contact position and trip indicators for ease of use
• Wide operating temperature range between -25°C and +60°C for use in harsh conditions

What's the ingress protection rating of this RCD switch?


This RCD switch has an IP40 rating, so it's protected against stray wires and screws. An IP54 rating is possible with the addition of a moisture-proof enclosure to help protect it from dust and water splashes.

Note

Eaton formerly known as Moeller

Liens connexes