Siemens Residual Current Circuit Breaker with Overload Protection, 16A Current Rating, 2-Pole, 30 mA Trip Sensitivity,
- N° de stock RS:
- 211-9610
- Référence fabricant:
- 5SU1354-4KK16
- Fabricant:
- Siemens
Sous-total (1 unité)*
222,20 €
(TVA exclue)
268,86 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 3 unité(s) expédiée(s) à partir du 19 novembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 222,20 € |
*Prix donné à titre indicatif
Notre gamme de produits Better World vous facilite l'accès à des produits plus durables et plus fiables.
En savoir plus sur les produits RS Better World
- N° de stock RS:
- 211-9610
- Référence fabricant:
- 5SU1354-4KK16
- Fabricant:
- Siemens
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Siemens | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Current Rating | 16A | |
| Range | SENTRON | |
| Number of Poles | 2 | |
| Series | 5SU1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Class C | |
| Rated AC Voltage | 230V ac | |
| Terminal Type | Screw | |
| Width | 36mm | |
| Height | 90mm | |
| Depth | 77mm | |
| Better World Product | Yes | |
| Better World Claim | Extended Product Life | |
| Breaking Capacity | 10kA | |
| Standards/Approvals | No | |
| Sélectionner tout | ||
|---|---|---|
Marque Siemens | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Current Rating 16A | ||
Range SENTRON | ||
Number of Poles 2 | ||
Series 5SU1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Class C | ||
Rated AC Voltage 230V ac | ||
Terminal Type Screw | ||
Width 36mm | ||
Height 90mm | ||
Depth 77mm | ||
Better World Product Yes | ||
Better World Claim Extended Product Life | ||
Breaking Capacity 10kA | ||
Standards/Approvals No | ||
- Pays d'origine :
- RO
Siemens 5SU1 Series Residual Current Circuit Breaker With Overload Protection, 16A Current, 30mA Trip sensitivity - 5SU1354-4KK16
Features and Benefits:
• 30 mA trip sensitivity reduces risk from residual currents
• Class C tripping characteristic handles moderate inrush currents
• 16 A rated operational current supports common circuit loads
• Screw terminals accept up to 35 mm² conductors for secure connections
Applications
• Used for circuits requiring combined earth-fault and overload protection
• Suitable for installations needing a Compact DIN-rail device
• Can be used where neutral-conductor switching is required
What ambient temperature range can it operate within?
How does the device perform under short-circuit conditions?
What conductor types and sizes are supported by the terminals?
How is the product tested for lower supply voltages?
What mechanical lifecycle can be expected from operation?
Liens connexes
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 2-Pole