Schneider Electric Modicon OTB Series I/O Module

Actuellement indisponible
Nous ne savons pas si cet article sera de nouveau disponible. RS a l'intention de le retirer de son assortiment sous peu.
N° de stock RS:
612-0194
Référence fabricant:
OTB1C0DM9LP
Fabricant:
Schneider Electric
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Schneider Electric

Product Type

I/O Module

Series

Modicon OTB

IP Rating

IP20

Standards/Approvals

CE,CSA,UL 508,EN 61131-2,CSA C22.2 No 213 Class I Division 2 Group D,CSA C22.2 No 213 Class I Division 2 Group B,CSA C22.2 No 213,Class I Division 2 Group A,IEC 61131-2,CSA C22.2 No 213 Class I Division 2 Group C

Pays d'origine :
FR

OTB CANopen interface module


Optimised Terminal Block (OTB) Interface Modules


3 Communication base modules each with 20 I/O

Expandable using 8 to 32 channel I/O modules (up to 264 channels)

Wide range of digital and analogue I/O's that are common to the Twido Logic Controllers

Direct mounting on DIN rail

Connectivity to fieldbus: CANopen, Modbus and Ethernet

IP20 rated

Removable screw terminal

Dimensions: H90mm x W55mm x D70mm

Maximum no. of I/O:

Power supply (non-isolated): 24Vdc

132 with screw/spring terminal digital I/O

244 with HE10 type connector digital I/O

48 analogue I/O (24 input/24 output channels)

Schneider Electric Advantys


The Advantys range of distributed I/O and interface products from Schneider Electric eliminate traditional wiring methods and reduce associated time and costs by placing I/O connection interfaces in close proximity to sensors and actuators within an application.The Advantys OTB distributed I/O solution consists of a compact system (network interface and integrated I/O) with the addition of Twido I/O expansion modules.,To simplify sensor and actuator connections as well as linking commons, the Advantys OTB offer includes a commoning module (stock no. 612-0223). This module allows the through connection of the internal bus or network and enables connection of the commons in two isolated groups.,Configuration of I/O is made using respective controller software but to aid with this a separate configuration tool is available for the Twido controller.,Each base incorporates 20 I/O:

A network interface module (including CANopen) with 12 inputs x 24V, 6 relay outputs and 2 solid state outputs x 24V-0.3 A

As an extension, up to 7 discrete or analogue I/O expansion modules can be added.

Note

To connect OTB1C0DM9LP (stock no. 612-0201 ) to a CAN network use connector TSXCANKCDF90T (stock no. 612-0425)