Fluke calibration 8808A/TL 240V 8808A Bench Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac
- N° de stock RS:
- 260-2715
- Référence fabricant:
- FLUKE 8808A/TL 240V
- Fabricant:
- Fluke calibration
Sous-total (1 unité)*
1 314,00 €
(TVA exclue)
1 589,94 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- Expédition à partir du 02 octobre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 1 314,00 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 260-2715
- Référence fabricant:
- FLUKE 8808A/TL 240V
- Fabricant:
- Fluke calibration
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Fluke calibration | |
| Product Type | Multimeter | |
| Multimeter Type | Bench | |
| Display Type | Digital | |
| Model Number | 8808A/TL 240V | |
| Resistance Resolution | 1mΩ | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 750V ac | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum Resistance Measurement | 100mΩ | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| AC Current Accuracy | ±0.3 % rdg | |
| DC Current Accuracy | 0.02 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| AC Current Resolution | 100μA ac | |
| DC Current Resolution | 1nA ac | |
| DC Voltage Resolution | 1 μV | |
| AC Voltage Resolution | 1V ac | |
| Maximum Frequency | 440Hz | |
| Minimum Operating Temperature | 0°C | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Length | 297mm | |
| Height | 88mm | |
| Weight | 2.1kg | |
| Standards/Approvals | ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | |
| Width | 217mm | |
| Series | 8808A | |
| Safety Category Level | Connector Bracket, Joint | |
| Safety Category Voltage | 1000V dc | |
| Sélectionner tout | ||
|---|---|---|
Marque Fluke calibration | ||
Product Type Multimeter | ||
Multimeter Type Bench | ||
Display Type Digital | ||
Model Number 8808A/TL 240V | ||
Resistance Resolution 1mΩ | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 750V ac | ||
Maximum AC Current Measurement 10A ac | ||
Maximum Resistance Measurement 100mΩ | ||
Maximum DC Current Measurement 10A dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
AC Voltage Accuracy ±0.2 % rdg | ||
AC Current Accuracy ±0.3 % rdg | ||
DC Current Accuracy 0.02 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
AC Current Resolution 100μA ac | ||
DC Current Resolution 1nA ac | ||
DC Voltage Resolution 1 μV | ||
AC Voltage Resolution 1V ac | ||
Maximum Frequency 440Hz | ||
Minimum Operating Temperature 0°C | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Length 297mm | ||
Height 88mm | ||
Weight 2.1kg | ||
Standards/Approvals ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | ||
Width 217mm | ||
Series 8808A | ||
Safety Category Level Connector Bracket, Joint | ||
Safety Category Voltage 1000V dc | ||
- Pays d'origine :
- CN
Fluke 8808A Series Multimeter, 1000V Safety Category Voltage, 10A Maximum DC Current Measurement - FLUKE 8808A/TL 240V
Features and Benefits:
• 1μV DC resolution facilitates detection of very small voltage changes
• 10A AC/DC current measurement supports power and load testing
• 100 mΩ low‑resistance range allows sensitive contact‑resistance checks
• 1 kV DC maximum rating permits high‑voltage component evaluation
• ±0.3% AC current accuracy ensures reliable alternating‑current readings
Applications
• Ideal for calibration laboratories requiring fine DC resolution
• Used with temperature sensors for thermal characterisation
• Can be used for capacitor testing during quality inspection
• Suitable for frequency response checks up to 440 Hz
What safety categories and approvals does it meet?
How does the display and form factor support bench use?
What are the environmental operating constraints?
What measurement resolutions are available for resistance and AC voltage?
Liens connexes
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS 10 A dc, 750 V ac - UKAS Calibrated
- Fluke calibration 8808A/TL 240V Bench Digital Multimeter True RMS 10 A dc, 750 V ac - RSCAL Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS 10 A dc, 1 kV ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac - RSCAL Calibrated
- Fluke calibration 8808A Bench Digital Multimeter True RMS 10 A dc, 750 V ac - UKAS Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS 10 A dc, 1 kV ac - UKAS Calibrated
- Fluke calibration 8808A/SU Bench Digital Multimeter True RMS 10 A dc, 1 kV ac - RSCAL Calibrated