Gossen Metrawatt M274S Digital Multimeter True RMS, 1 A, 1 A, 1 kV ac
- N° de stock RS:
- 219-887
- Numéro d'article Distrelec:
- 302-17-042
- Référence fabricant:
- M274S
- Fabricant:
- Gossen Metrawatt
Sous-total (1 unité)*
2 769,42 €
(TVA exclue)
3 351,00 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 90,00 €
- 5 unité(s) expédiée(s) à partir du 23 novembre 2026
- Plus 2 unité(s) expédiée(s) à partir du 26 novembre 2026
Unité | Prix par unité |
|---|---|
| 1 + | 2 769,42 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 219-887
- Numéro d'article Distrelec:
- 302-17-042
- Référence fabricant:
- M274S
- Fabricant:
- Gossen Metrawatt
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Gossen Metrawatt | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Resistance Resolution | 0.10Ω | |
| Display Type | Digital | |
| Model Number | M274S | |
| Functions Measured | AC Current, AC Voltage, Continuity, DC Voltage, Diode Test, Frequency, Inrush Current, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum DC Current Measurement | 1A | |
| Maximum AC Current Measurement | 1A | |
| Maximum Resistance Measurement | 30000kΩ | |
| Maximum DC Voltage Measurement | 1kV dc | |
| True RMS | Yes | |
| AC Current Accuracy | 1.0+30 % rdg. + d | |
| AC Voltage Accuracy | ±0.15 % rdg + 10 Digits | |
| DC Voltage Accuracy | 0.15 % rdg +10 Digits, ±0.2 % rdg +20 Digits | |
| DC Current Resolution | 10nA | |
| AC Current Resolution | 10nA | |
| AC Voltage Resolution | 0.01mV | |
| DC Voltage Resolution | 0.01 mV | |
| Maximum Frequency | 300kHz | |
| Power Source | Battery, USB | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 20h | |
| Width | 105mm | |
| Weight | 700g | |
| Length | 235mm | |
| Height | 56mm | |
| Standards/Approvals | CE, DAkkS Calibration Certificate | |
| Safety Category Level | CAT III, CAT IV | |
| Other Measurement Range | Inductance with COIL adapter: 10 μH to 50 mH, 10 μH to 5 H | |
| Battery Type | Lithium-Polymer, 3.7 V | |
| Safety Category Voltage | 1000V ac | |
| Sélectionner tout | ||
|---|---|---|
Marque Gossen Metrawatt | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Resistance Resolution 0.10Ω | ||
Display Type Digital | ||
Model Number M274S | ||
Functions Measured AC Current, AC Voltage, Continuity, DC Voltage, Diode Test, Frequency, Inrush Current, Resistance, Temperature | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum DC Current Measurement 1A | ||
Maximum AC Current Measurement 1A | ||
Maximum Resistance Measurement 30000kΩ | ||
Maximum DC Voltage Measurement 1kV dc | ||
True RMS Yes | ||
AC Current Accuracy 1.0+30 % rdg. + d | ||
AC Voltage Accuracy ±0.15 % rdg + 10 Digits | ||
DC Voltage Accuracy 0.15 % rdg +10 Digits, ±0.2 % rdg +20 Digits | ||
DC Current Resolution 10nA | ||
AC Current Resolution 10nA | ||
AC Voltage Resolution 0.01mV | ||
DC Voltage Resolution 0.01 mV | ||
Maximum Frequency 300kHz | ||
Power Source Battery, USB | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Battery Life 20h | ||
Width 105mm | ||
Weight 700g | ||
Length 235mm | ||
Height 56mm | ||
Standards/Approvals CE, DAkkS Calibration Certificate | ||
Safety Category Level CAT III, CAT IV | ||
Other Measurement Range Inductance with COIL adapter: 10 μH to 50 mH, 10 μH to 5 H | ||
Battery Type Lithium-Polymer, 3.7 V | ||
Safety Category Voltage 1000V ac | ||
- Pays d'origine :
- DE
Gossen-Metrawatt Multimeter, 1000V Maximum AC Voltage, 1A Maximum DC Current - M274S
Features and Benefits:
• 0.15% DC voltage accuracy for precise measurement
• True RMS capability for accurate AC waveform readings
• 300kHz maximum frequency for high-frequency signal analysis
• Lithium‑polymer battery with 20 h runtime for extended field use
• 1000 V safety rating for CAT III and CAT IV environments
Applications
• Ideal for testing in distribution boards and switchgear
• Used for motor start investigations including inrush current
• Can be used with Coil adaptor for inductance testing
• Used for calibration checks with supplied DAkkS certificate
What power sources does it accept for operation?
What measurement ranges are available for resistance and inductance?
How does the instrument handle current measurement?
What environmental temperatures can it operate within?
What approvals and documentation accompany the device?
Liens connexes
- Gossen Metrawatt M274S Handheld Multimeter True RMS 3 mA dc RSCAL Calibrated
- Gossen Metrawatt M274S Handheld Multimeter True RMS 3 mA dc UKAS Calibrated
- Gossen Metrawatt Handheld Multimeter True RMS
- Gossen Metrawatt M246B Handheld Multimeter True RMS
- Gossen Metrawatt Handheld Multimeter True RMS, UKAS Calibrated
- Gossen Metrawatt Handheld Multimeter True RMS, RSCAL Calibrated
- Gossen Metrawatt METRAHit ENERGY Handheld Multimeter True RMS
- Gossen Metrawatt METRAHit 2+ Handheld Multimeter True RMS