Eaton xEffect MCB, 1+N, 3A Curve C, 240V AC, 48V DC, 10 kA Breaking Capacity
- N° de stock RS:
- 922-7071
- Référence fabricant:
- 278664 FAZ-C3/1N
- Fabricant:
- Eaton
Sous-total (1 unité)*
55,65 €
(TVA exclue)
67,34 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
En stock
- 31 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 55,65 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 922-7071
- Référence fabricant:
- 278664 FAZ-C3/1N
- Fabricant:
- Eaton
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Eaton | |
| Number of Poles | 1+N | |
| Current Rating | 3A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Width | 66mm | |
| Length | 17.8mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Tripping Mechanism | Thermal-Magnetic | |
| Break Time | Instantaneous | |
| Terminal Contact Type | Screw | |
| Reset Actuator Type | Toggle Switch | |
| Sélectionner tout | ||
|---|---|---|
Marque Eaton | ||
Number of Poles 1+N | ||
Current Rating 3A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Width 66mm | ||
Length 17.8mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
Tripping Mechanism Thermal-Magnetic | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
Eaton MCB, Instantaneous Breaking Time, 1.3W Maximum Heat Loss - FAZ Series - 278664 FAZ-C3/1N
Make quick work of protecting your circuit with this MCB from Eaton. As soon as electrical issues pop up, it has two ways to instantly deal with them thanks to its thermal-magnetic mechanism. The thermal trip unit responds to an increase in temperature, while the magnetic element reacts to a hike in current. As this device breaks loads of up to 10kA, it shuts down large surge currents without a hitch. Support for AC and DC voltages makes it a flexible fit for industrial supplies. Due to the front-mounted toggles that control the live and neutral connections, resetting your system is done with the flick of a switch. You'll find MCBs like this one protecting systems in packing plants and data centres.
Features & Benefits
• Snaps onto a DIN rail for easy mounting
• Compact dimensions of 36 (W) x 75.5 (H) x 80mm (D) mean it slots easily into a crowded cabinet
• Light 200g weight doesn't add strain to your setup
• Compact dimensions of 36 (W) x 75.5 (H) x 80mm (D) mean it slots easily into a crowded cabinet
• Light 200g weight doesn't add strain to your setup
What's an MCB's tripping characteristic?
An MCB's tripping characteristic indicates how much overcurrent causes the unit to break the attached circuit. This device has a type-C curve, meaning it trips when it receives five to ten times its maximum rated load of 3A.
Note
Eaton formerly known as Moeller
Liens connexes
- Eaton xEffect MCB 3A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 3A Curve K 15 kA Breaking Capacity
- Eaton xEffect MCB 3A Curve D 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 3A Curve C
- Eaton xEffect FAZ MCB 63A Curve K 48V DC, 15 kA Breaking Capacity
- Eaton xEffect MCB 2A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 1A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 16A Curve C 48V DC, 10 kA Breaking Capacity