Schneider Electric Acti9 iC60L Miniature Circuit Breaker, 2-Pole, 16 A, Type C, 100 V, 12 V, 130 V, 220 V, 240 V, 380 V,

Sous-total (1 unité)*

122,15 €

(TVA exclue)

147,80 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
En stock
  • 14 unité(s) prête(s) à être expédiée(s) d'un autre centre de distribution
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +122,15 €

*Prix donné à titre indicatif

N° de stock RS:
734-9419
Référence fabricant:
A9F94216
Fabricant:
Schneider Electric
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Schneider Electric

Number of Poles

2

Product Type

Miniature Circuit Breaker

Current Rating

16 A

Tripping Characteristics

Type C

Rated AC Voltage

100 V, 12 V, 130 V, 220 V, 240 V, 380 V, 400 V, 415 V, 440 V, 60 V

Rated DC Voltage

12 V dc

Breaking Capacity

15kA

Mount Type

DIN Rail

Range

Acti9

Series

iC60L

Terminal Type

Screw

IP Rating

IP20

Width

36 mm

Standards/Approvals

EN/IEC 60898-1, EN/IEC 60947-2, REACH, RoHS

Depth

78.5mm

Height

85mm

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

Break Time

Instantaneous

Pays d'origine :
FR

Schneider Electric iC60L Series Acti 9 MCB, 16A Current Rating, 10kA Breaking Capacity (at Maximum Voltage Rating) - A9F94216


This MCB provides reliable protection for electrical installations. Designed for 2 pole configurations, it has a current rating of 16A. With dimensions of 36mm in width, this DIN rail mounted circuit breaker excels at safeguarding electrical circuits against overloads and short circuits.

Features & Benefits


• High breaking capacity of 15kA at 400V AC enhances safety

• Thermal-magnetic trip unit provides dependable protection

• Rated AC voltage support for a wide range of requirement

Applications


• Ideal for protecting lighting circuits in commercial buildings

• Suitable for machinery and industrial

• Utilised in electrical panels for distribution protection

• Suitable for both AC and DC networks for versatile

What are the specific breaking capacities for different voltage ratings?


The MCB has a breaking capacity of 15kA at 400V AC and up to 25kA at 220 to 240 V AC, ensuring robust circuit protection. It also supports breaking capacities of 20kA for both 125V DC and 440V AC.

How does the trip unit technology function in this device?


The thermal-magnetic trip unit operates by detecting excessive current flow, which triggers the mechanism to disconnect the circuit, offering both thermal and magnetic protection against overloads and short circuits.