Allen Bradley 1492-D2 1492-D MCB, 2P, 13A Curve C, 10 kA Breaking Capacity
- N° de stock RS:
- 218-8555
- Référence fabricant:
- 1492-D2C130
- Fabricant:
- Allen Bradley
Sous-total (1 unité)*
158,95 €
(TVA exclue)
192,33 €
(TVA incluse)
Frais de livraison offerts pour toute commande de plus de 75,00 €
Temporairement en rupture de stock
- Expédition à partir du 16 mars 2026
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité | Prix par unité |
|---|---|
| 1 + | 158,95 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 218-8555
- Référence fabricant:
- 1492-D2C130
- Fabricant:
- Allen Bradley
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Allen Bradley | |
| Number of Poles | 2 | |
| Current Rating | 13A | |
| Tripping Characteristics | Type C | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | 1492-D2 | |
| Series | 1492-D | |
| Circuit Breaker Type | MCB | |
| Width | 17.5mm | |
| Length | 88mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 69mm | |
| Model Number | 1492-D2C130 | |
| Sélectionner tout | ||
|---|---|---|
Marque Allen Bradley | ||
Number of Poles 2 | ||
Current Rating 13A | ||
Tripping Characteristics Type C | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range 1492-D2 | ||
Series 1492-D | ||
Circuit Breaker Type MCB | ||
Width 17.5mm | ||
Length 88mm | ||
Mounting Style DIN Rail Mount | ||
Depth 69mm | ||
Model Number 1492-D2C130 | ||
Statut RoHS non applicable
- Pays d'origine :
- DE
The Rockwell Automation 1492-D series miniature circuit breakers provide overcurrent and short circuit protection for higher voltage DC circuits. It has two pole and current rating of 13 may be used with UL 508 Listed bus bars for convenience in panel assembly, a wide range of left-, right- and space saving bottom-mount accessories, and lock out attachments for safety during maintenance.
Dual terminals provide a more secure connection of up to four wires, or two wires and a bus bar
Existing installations can be easily upgraded to include an auxiliary using the bottom mounted auxiliary contact options, which require no DIN Rail space
Installation of up to six accessories on the same circuit breaker
Superior shock and vibration resistance to prevent nuisance tripping
Terminal design helps prevent wiring misses by directing wires into the terminal openings, even while tightening
RoHS compliant and fully-recyclable device
Existing installations can be easily upgraded to include an auxiliary using the bottom mounted auxiliary contact options, which require no DIN Rail space
Installation of up to six accessories on the same circuit breaker
Superior shock and vibration resistance to prevent nuisance tripping
Terminal design helps prevent wiring misses by directing wires into the terminal openings, even while tightening
RoHS compliant and fully-recyclable device
Liens connexes
- Allen Bradley 1492-SP 1492-SPM MCB 13A Curve D
- Allen Bradley 1492-SP 1492-SPM MCB 13A Curve C
- Allen Bradley 1492-D2 1492-D MCB 4A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 3A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 6A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 16A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 8A Curve C, 10 kA Breaking Capacity
- Allen Bradley 1492-D2 1492-D MCB 25A Curve C, 10 kA Breaking Capacity