Omron D4n Series Rod Limit Switch, 2 NC, IP67, Plastic Housing, 240V ac, 2.5A

Sous-total (1 unité)*

35,66 €

(TVA exclue)

43,15 €

(TVA incluse)

Add to Basket
sélectionner ou taper la quantité
Temporairement en rupture de stock
  • Expédition à partir du 18 janvier 2027
Besoin de plus? Cliquez sur " Vérifier les dates de livraison " pour plus de détails
Unité
Prix par unité
1 +35,66 €

*Prix donné à titre indicatif

N° de stock RS:
288-3215
Référence fabricant:
D4N-4287
Fabricant:
Omron
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout

Marque

Omron

Product Type

Limit Switch

Actuator Type

Rod

Contact Configuration

2 NC

IP Rating

IP67

Housing Material

Plastic

Contact Type

2 NC

Switching Current

2.5A

Terminal Type

Terminal Block

Series

D4n

Minimum Operating Temperature

-30°C

Switching AC Voltage

240V ac

Switching DC Voltage

250V dc

Maximum Operating Temperature

+70°C

Standards/Approvals

CE, cULus

Hazardous Area Certification

No

Mechanical Life

15000000Cycles

Statut RoHS : Exempté

Pays d'origine :
JP

Omron D4n Series Limit Switch, IP67, 15000000 cycles Mechanical Life - D4N-4287


This limit switch is a mechanical actuator device designed to detect position changes and interrupt circuits in industrial settings. It uses a rod-style actuator housed in a plastic enclosure with protection against dust and water ingress, and it operates across a wide ambient temperature range for use in varied environments.

Features and Benefits:


• Rod actuator provides precise mechanical position detection
• IP67 protection enables use in wet or dusty locations
• Two normally closed contacts offer straightforward fail-safe wiring
• Switching capability supports 250VDC and 240VAC circuits
• 2.5A switching current suits modest control and signalling loads
• Mechanical endurance rated for 15,000,000 cycles reduces maintenance

Applications


• Suitable for conveyor end-of-travel sensing in factories
• Used with automated doors for travel limit control
• Ideal for packaging machines requiring position feedback
• Can be used for safety interlocks on laboratory equipment
• Used for simple PLC input signalling in control panels

What connection method does it use for wiring?


It employs a terminal-block arrangement for secure field wiring.

How does the contact arrangement affect circuit design?


The pair of normally closed contacts allows series wiring for safety circuits and straightforward monitoring of open conditions.

What environmental temperatures can it tolerate during operation?


It is specified to function between -30°C and +70°C for ambient conditions.

What approvals cover its conformity to safety standards?


It holds CE and cULus approvals indicating compliance with relevant European and North American requirements.

Liens connexes

Soyez le/la premier·ère à être informé de nos nouveautés produits et de nos offres spéciales.

adresse e-mail

Les données personnelles que vous nous fournissez en vous inscrivant à cette liste de diffusion seront traitées conformément à notre politique de confidentialité.