Eaton LS-Titan Series Plunger Limit Switch, 1 NO/1 NC, IP67, IP66, Plastic Housing, 415V ac, 6A
- N° de stock RS:
- 308-266
- Numéro d'article Distrelec:
- 304-10-388
- Référence fabricant:
- 266109 LS-11
- Fabricant:
- Eaton
Sous-total (1 unité)*
25,00 €
(TVA exclue)
30,25 €
(TVA incluse)
Informations sur le stock actuellement non accessibles - Veuillez vérifier plus tard
Unité | Prix par unité |
|---|---|
| 1 + | 25,00 € |
*Prix donné à titre indicatif
- N° de stock RS:
- 308-266
- Numéro d'article Distrelec:
- 304-10-388
- Référence fabricant:
- 266109 LS-11
- Fabricant:
- Eaton
Spécifications
Documentation technique
Législations et de normes
Détails du produit
Recherchez des produits similaires en sélectionnant un ou plusieurs attributs.
Sélectionner tout | Attribut | Valeur |
|---|---|---|
| Marque | Eaton | |
| Actuator Type | Plunger | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP67, IP66 | |
| Housing Material | Plastic | |
| Contact Type | Slow Action | |
| Terminal Type | Cage Clamp | |
| Switching Current | 6A | |
| Series | LS-Titan | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 220V dc | |
| Switching AC Voltage | 415V ac | |
| Maximum Operating Temperature | 70°C | |
| Length | 33.5mm | |
| Width | 31mm | |
| Depth | 76.5mm | |
| Standards/Approvals | EN/IEC | |
| Hazardous Area Certification | NO | |
| Mechanical Life | 8000000Cycles | |
| Operating Force | 1N | |
| Sélectionner tout | ||
|---|---|---|
Marque Eaton | ||
Actuator Type Plunger | ||
Product Type Limit Switch | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP67, IP66 | ||
Housing Material Plastic | ||
Contact Type Slow Action | ||
Terminal Type Cage Clamp | ||
Switching Current 6A | ||
Series LS-Titan | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 220V dc | ||
Switching AC Voltage 415V ac | ||
Maximum Operating Temperature 70°C | ||
Length 33.5mm | ||
Width 31mm | ||
Depth 76.5mm | ||
Standards/Approvals EN/IEC | ||
Hazardous Area Certification NO | ||
Mechanical Life 8000000Cycles | ||
Operating Force 1N | ||
Eaton Snap-Action Plunger Limit Switch, AC/DC - LS Series - LS-11
This limit switch from Eaton is designed to sense the position of an object in industrial applications. As the object makes contact with the plunger on the unit, electrical contacts are opened or closed (depending on the configuration), enabling it to control the machinery. This mechanical switch consumes less electricity and isn't as prone to breakdowns, making it a simple and efficient way to count objects or regulate their limit of travel. You'll find this type of switch on production lines, electrical assembly equipment and escalators.
• IP66 (ingress protection) rating means it's safe for harsh environments
• Choice of eight positions for operating heads for extra flexibility
• Snap-action contacts avoid arcing and false signalling
• Wide operating temperature range of -25°C to +70°C
• Cage clamp connectors are easy to install and maintenance-free
Are these switches normally open or normally closed?
These limit switches can be set as either NO or NC. When used in the normally closed configuration, they can provide a safety function to IEC/EN 60947-5-1 standards.
Is a plunger-type limit switch the right choice for my application?
Plunger-type position switches are best for short, controlled machine movements or applications where there is insufficient mounting space for a lever-type switch.
Eaton Plastic Body Titan Limit Switch
This range of easy to use limit switches by Eaton offer a variety of compact safety position switches to suit worldwide application.
Features and Benefits
• Eaton's limit switch has an IP66 protection rating in plastic bodies
• Operating heads can be installed in a choice of 8 positions
• The limit switch is suitable for use with electronic devices
• The switches have maintenance-free and vibration proof cage clamp terminals
• Standard action or snap-action contacts, with early break (EB) or late break (LB) options available
• Interlocked opposing contacts for positive operation
• LSE versions include an electronically adjustable operating point and visible status display
Uses and Applications
A limit switch is made up of an actuator head, switch body and receptacle, and is used to control machinery as part of a control system in many types of industrial applications. Limit switch uses include:
• Escalators
• Food and beverage industry
• Electrical assembly equipment
• Material handling
Liens connexes
- Eaton, 415V ac
- Eaton LS-Titan Series Plunger Limit Switch Insulated Plastic Housing 6 A
- Eaton, 415V ac AC
- Coral Google Mini PCIe M.2 Accelerator B/M Development Kit G650-04686-01
- Littelfuse Through Hole Gas Discharge Tube
- SICK Encoder Collets for Use with DBS36E-BBxxxx
- Igus GFM-0607-08 6mm Bore Plain Bearing, 7mm O.D
- Herga General Purpose Momentary Foot Switch - Thermoplastic Case Material 3 A@ 250 V ac Contact Current, 250V